Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background/introduction: Currently, despite continued issues with durability ( 1), biological prosthetic valves are increasingly chosen over mechanical valves for surgical aortic valve replacement (SAVR) in adult patients of all ages, at least in Western countries. For younger patients, this choice means assuming the risks associated with a redo SAVR or valve-in-valve procedure.
Purpose: To assess the use of mechanical vs. biological valve prostheses for SAVR relative to patient's age and implant time in a large population extracted from the French National Database EPICARD.
Methods: Patients in EPICARD undergoing SAVR from 2007 to 2022 were included from 22 participating public or private centers chosen to represent a balanced representation of centre sizes and geographical discrepancies. Patients with associated pathology of the aorta (aneurysm or dissection) and requiring a vascular aortic prosthesis were excluded. Comparisons were made amongst centers, valve choice, implant date range, and patient age.
Results: We considered 101,070 valvular heart disease patients and included 72,375 SAVR (mean age 71.4 ± 12.2 years). We observed a mechanical vs. biological prosthesis ratio (MBPR) of 0.14 for the overall population. Before 50 years old (y-o), MBPR was >1.3 ( < 0.001) while patients above 60 years-old received principally biological SAVR ( < 0.0001). Concerning patients between 50 and 60 years-old patients, MPVR was 1.04 ( = 0.03). Patients 50-60 years-old from the first and second study duration quartile (before August 2015) received preferentially mechanical SAVR ( < 0.001). We observed a shift towards more biological SAVR ( < 0.001) for patients from the third and fourth quartile to reach a MBPR at 0.43 during the last years of the series. Incidentally, simultaneous mitral valve replacement were more common in case of mechanical SAVR ( < 0.0001), while associated CABGs were more frequent in case of biological SAVR ( < 0.0001).
Conclusion: In a large contemporary French patient population, real world practice showed a recent shift towards a lower age-threshold for biological SAVR as compared to what would suggest contemporary guidelines.