Purpose: To compare the accuracy of occlusal stabilization appliances fabricated by digital workflows to those fabricated by conventional workflows.

Materials And Methods: In total, 10 volunteers were recruited in this single-blinded crossover study. All volunteers received two types of occlusal stabilization appliances: a digital additively manufactured stabilization splint (DS) and a conventionally fabricated splint (CS). The accuracy was assessed using a 4-point rating scale addressing two aspects of the occlusal appliances: occlusal contact and basic performance. In addition, silicone impression materials were used to assess the gap between the appliance and the maxillary arch to ensure an accurate fit. Differences were quantitatively assessed with Mann-Whitney U test and independent-sample t test.

Results: The occlusal contact rating of DS (15.90 ± 1.73) was significantly higher than that of CS (14.10 ± 1.10, P < .05). The basic performance rating of DS (8.70 ± 0.48) was also significantly higher than that of CS (7.20 ± 0.92. P < .05). Quantitative evaluation of fit accuracy revealed a statistically significant difference (P < .05), with DS (636.29 ± 268.51 μm) being superior to CS (704.2 ± 306.05 μm).

Conclusion: The stabilization splints fabricated with a digital workflow showed better accuracy than the conventionally fabricated splints in terms of occlusal contact, basic performance, and fit accuracy. Because this is a pilot study, formal trials with a completely digital fabrication workflow will be conducted in the future.

Download full-text PDF

Source
http://dx.doi.org/10.11607/ijp.7947DOI Listing

Publication Analysis

Top Keywords

fabrication workflow
12
occlusal contact
12
basic performance
12
digital fabrication
8
occlusal appliances
8
pilot study
8
occlusal stabilization
8
stabilization appliances
8
fabricated digital
8
conventionally fabricated
8

Similar Publications

The preoperative fabrication of well-contoured, computer-aided design and computer-aided manufacturing (CAD-CAM), custom healing abutments is essential for guiding soft tissue healing and saving chairside time. This dental technique involves a fully digital workflow to fabricate a CAD-CAM custom healing abutment that relies on preoperative digital implant planning. The healing abutment is designed with an optimal emergence profile that can predictably direct the anatomy of the peri-implant mucosa.

View Article and Find Full Text PDF

The CRISPR-Cas12a system has shown tremendous potential for developing efficient biosensors. Albeit important, current CRISPR-Cas system-based diagnostic technologies (CRISPR-DX) highly rely on an additional preamplification procedure to obtain high sensitivity, inevitably leading to issues such as complicated assay workflow, cross-contamination, etc. Herein, a spherical protospacer-adjacent motif (PAM)-antenna-enhanced CRISPR-Cas12a system is fabricated for universal amplification-free nucleic acid detection with a detection limit of subfemtomolar.

View Article and Find Full Text PDF

Clinical Considerations: Conventional facebow records are used to transfer the maxillary cast into the analog articulator. Different reference planes have been described, including the true horizontal or gravity reference plane. A conventional facebow (Kois Dentofacial Analyzer; Panadent) allows the recording of the gravity plane for transferring the maxillary cast into the analog semi-adjustable articulator.

View Article and Find Full Text PDF

Physical unclonable functions (PUFs) are of immense potential in authentication scenarios for Internet of Things (IoT) devices. For creditable and lightweight PUF applications, key attributes, including low power, high reconfigurability and large challenge-response pair (CRP) space, are desirable. Here, we report a ferroelectric field-effect transistor (FeFET)-based strong PUF with high reconfigurability and low power, which leverages the FeFET cycle-to-cycle variation throughout the workflow and introduces charge-domain in-memory computing.

View Article and Find Full Text PDF

CAD-CAM complete digital dentures: An improved clinical and laboratory workflow.

J Prosthet Dent

December 2024

Associate Professor and Department Head, Department of Prosthodontics, University of Ferrara, Ferrara, Italy.

The purpose of this article was to present a novel clinical workflow for the fabrication of complete dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) technology. The dental technique consists of 3 clinical steps and 2 laboratory phases that result in the production of 2 CAD-CAM milled complete denture bases with prefabricated teeth. The integration of analog and digital procedures and materials maximizes their benefits in the planning and fabrication of complete dentures, with the goal of improving clinical outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!