A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A death due to faulty airbag system-case report. | LitMetric

A death due to faulty airbag system-case report.

Forensic Sci Med Pathol

Department of Forensic Medicine, Faculty of Medicine, University of Peradeniya, Peradeniya, Kandy, Sri Lanka.

Published: September 2024

Injuries due to automobile safety devices have been reported and we report a rare fatality due to a defective airbag system. A compact hybrid car driven by a 37-year-old male at moderate speed had crashed through an unprotected manhole. The car had moved around 200 m before it came to a halt. The passers-by had noticed that the driver was unconscious, partly leaning forward with an inflated airbag. He was pronounced dead on admission. The car had sustained minor indentation on front bumper. Autopsy revealed a circular perforated laceration on the neck associated with completely transected right carotid artery and partially transected jugular vein. There was a 2 × 2-cm cylindrical metal object lodged at C-C vertebrae level, and the remaining part of this was retrieved during scene investigation and identified as a part of a metal canister in the inflator component of the airbag system. There was a perforation in the airbag which was similar in size to the retrieved foreign body. The cause of death was ascertained as hemorrhagic shock due to bleeding from ruptured neck vessels caused by primary shrapnel projected from the faulty airbag system. Following the incident, the manufacturers replaced faulty airbag systems in similar models. If abnormally fatal injuries are observed, a scene visit along with automotive expert opinion would provide valuable insight into the incident. Such information would alert the general public on regular screening of safety measures and prompt manufacturers to recall faulty products.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12024-023-00715-1DOI Listing

Publication Analysis

Top Keywords

faulty airbag
12
airbag system
12
airbag
7
death faulty
4
airbag system-case
4
system-case report
4
report injuries
4
injuries automobile
4
automobile safety
4
safety devices
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!