A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Outcomes of Combined Phacovitrectomy Without Corneal Suturing. | LitMetric

Outcomes of Combined Phacovitrectomy Without Corneal Suturing.

Isr Med Assoc J

Department of Ophthalmology, Rabin Medical Center (Beilinson Campus), Petah Tikva, Israel, Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.

Published: September 2023

AI Article Synopsis

  • During combined phacovitrectomy, suturing the main corneal incision is typically done to avoid leaks, but this study explores the use of a self-sealing technique instead.
  • The study reviewed cases from a university hospital where surgeons performed surgeries without planned sutures, only using them if needed due to complications.
  • Results showed that only 5% of cases required suturing for leaks, indicating that preventive suturing may not be necessary and can be selectively applied when complications occur.

Article Abstract

Background: During combined phacovitrectomy, it is common practice to suture the main corneal incision to prevent intraoperative and postoperative wound leak. However, it may be possible to avoid suturing using a self-sealing corneal incision technique as in standard cataract surgery.

Objectives: To evaluate the clinical outcome, safety, and complications of combined phacovitrectomy without preventive suturing.

Methods: This retrospective case series study included consecutive patients who underwent combined phacovitrectomy between January 2018 and June 2019 for mixed indications. Surgeries were performed at a tertiary university hospital. All surgeries were performed by the same two retinal surgeons. Cataract surgery was performed first, followed by insertion of trocars and vitrectomy. Corneal sutures were not planned but were used at the discretion of the surgeon.

Results: The cohort included 106 eyes of 102 patients. Suturing of the main corneal incision was deemed necessary in five cases (5%) because of a main incision leak or anterior chamber shallowing during trocar insertion. No other complications related to the absence of prophylactic corneal sutures were encountered during surgery or follow-up.

Conclusions: Preventive corneal suturing may not be necessary in combined phacovitrectomy surgery and can be used in the few cases in which it is indicated during surgery.

Download full-text PDF

Source

Publication Analysis

Top Keywords

combined phacovitrectomy
20
corneal incision
12
corneal suturing
8
main corneal
8
surgeries performed
8
corneal sutures
8
corneal
7
phacovitrectomy
5
outcomes combined
4
phacovitrectomy corneal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!