Using full configuration interaction (FCI) and multi-reference configuration interaction methods (MRCI), reliable geometrical and energetic references for B (n = 1-4) clusters were established. The accuracy of the computed results was confirmed by comparison with available experimental data. Benchmark calculations indicated that B97D3, B97D, VSXC, HCTH407, BP86 and CCSD(T) methods provided reasonable results for structural parameters, with mean absolute error (MAEs) within 0.020 Å. Among the tested density functional theory (DFT) methods, the VSXC functional showed the best performance in predicting the relative energies of B B with a MAE of 12.8 kJ mol . Besides, B1B95, B971, TPSS, B3LYP, and BLYP functionals exhibited reasonable performance with MAE values of less than 15.0 kJ mol . T diagnostic values between 0.035 and 0.109 at the CCSD(T) level revealed strong correlations in B B clusters, highlighting the need for caution in using CCSD(T) as an energy reference for small boron clusters. The methods of CCSDT, CCSDT(Q) and CCSDT[Q], which incorporate three-electron and four-electron excitations, effectively improved the accuracy of the energy calculations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jcc.27226 | DOI Listing |
JMIR Form Res
January 2025
Department of Psychology, The University of Texas at San Antonio, San Antonio, TX, United States.
Background: Perception-related errors comprise most diagnostic mistakes in radiology. To mitigate this problem, radiologists use personalized and high-dimensional visual search strategies, otherwise known as search patterns. Qualitative descriptions of these search patterns, which involve the physician verbalizing or annotating the order he or she analyzes the image, can be unreliable due to discrepancies in what is reported versus the actual visual patterns.
View Article and Find Full Text PDFACS Appl Electron Mater
January 2025
Electrical Engineering Division, Engineering Department, University of Cambridge, Cambridge CB3 0FA, U.K.
Nanoscale semiconductors offer significant advantages over their bulk semiconductor equivalents for electronic devices as a result of the ability to geometrically tune electronic properties, the absence of internal grain boundaries, and the very low absolute number of defects that are present in such small volumes of material. However, these advantages can only be realized if reliable contacts can be made to the nanoscale semiconductor using a scalable, low-cost process. Although there are many low-cost "bottom-up" techniques for directly growing nanomaterials, the fabrication of contacts at the nanoscale usually requires expensive and slow techniques like e-beam lithography that are also hard to scale to a level of throughput that is required for commercialization.
View Article and Find Full Text PDFEur Spine J
January 2025
Department of Industrial and Systems Engineering, Auburn University, 3301 Shelby Center, Auburn, AL, 36849-5346, USA.
Background: Magnetic resonance imaging (MRI) is increasingly used to estimate the geometric dimensions of lower lumbar vertebrae. While MRI-based measurements have demonstrated good reliability with interclass correlation coefficients (ICCs) of 0.80 or higher, many evaluations focus solely on the comparison of identical MRI images.
View Article and Find Full Text PDFJ Mol Model
January 2025
Escuela Superior de Física y Matemáticas, IPN S/N, Edificio 9 de la Unidad Profesional "Adolfo López Mateos", Col. Lindavista, Alc. Gustavo A. Madero, 07738, Mexico City, Mexico.
Context: "Nanostructure of graphene-reinforced with polymethyl methacrylate" (PMMA-G), and vice versa, is investigated using its molecular structure, in the present work. The PMMA-G nanostructure was constructed by bonding PMMA with graphene nanosheet in a sense to get three different configurations. Each configuration consisted of polymeric structures with three degrees of polymerization (such as monomers, dimers, and trimers polymers, respectively).
View Article and Find Full Text PDFJPRAS Open
March 2025
Department of Plastic and Craniofacial Surgery, MITERA Hospital, Hellenic Healthcare Group (HHG), 6 Erithrou Stavrou str., 151 23 Maroussi, Attica, Greece.
Background: Despite a variety of principles proposed for drawing trilobed and quadrilobed flaps for the reconstruction of nasal skin defects, the application of these principles in a detailed and reliable way remains questionable.
Methods: We present a novel method for drawing trilobed and quadrilobed flaps to cover nasal tip skin defects. The method is based on the use of templates corresponding to four trilobed flaps with overall angles of 60°, 70°, 80°, and 90°, and two quadrilobed flaps with angles of 90° and 105°.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!