Background: Indoor airborne fungi are a significant health concern that can cause respiratory symptoms and other health problems. Indoor fungi are influenced by various factors such as meteorological conditions and dwelling characteristics.
Objective: This study aims to evaluate the association between indoor airborne fungi and environmental factors in a student dormitory in southern Thailand.
Material And Methods: The study was conducted at Walailak University in southern Thailand from September toDecember 2020. Air samples were collected from rooms in thirteen dormitories, and the fungal load was determined using the passive air sampling method. The study also measured meteorological parameters and gathered data on occupant behaviors and exposure-related symptoms through a self-administered questionnaire.
Results: In a total of 135 student rooms, the average concentration (mean ± SD) of indoor airborne fungi was 409.72±176.22 CFU/m3, which showed the highest concentration on the first floor. For meteorological parameters, the averages of RH (%), temperature (°C), and CO2 (ppm) were 70.99±2.37, 31.11±0.56 and 413.29±76.72, respectively. The abundance of indoor airborne fungi was positively associated with an increase in RH (β=0.267, 95% CI: 5.288, 34.401) and building height (β=0.269, 95% CI: 16.283, 105.873), with values of 19.845 and 61.078, respectively. Conversely, temperature exhibited a negative effect on indoor airborne fungi (-92.224, β=-0.292, 95% CI: -150.052, -34.396).
Conclusion: The findings highlight the influence of RH, temperature and building height on indoor airborne fungi in the student dormitory. Therefore, effective management strategies are necessary to improve indoor air quality and reduce associated health risks in student dormitories.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.32394/rpzh.2023.0273 | DOI Listing |
Environ Pollut
January 2025
State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, Sichuan province, China. Electronic address:
Dental operations inherently involve a high risk of airborne cross-infection among medical staff and patients due to the exposure of respiratory secretions, which contain pathogenic microorganisms and typically spread in the form of aerosols. In order to contribute to the understanding of aerosol dynamics during dental operation and efficiently mitigate their dispersion and deposition through appropriate ventilation, 3D numerical simulations and full-scale experimental measurements were performed in this study. The indoor airflow distribution and dynamic aerosol behaviors observed under three optimized ventilation schemes (Scenario I-III) were compared with those observed under the current ventilation system.
View Article and Find Full Text PDFJ Hazard Mater
December 2024
SCNU Environmental Research Institute, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China; School of Environment, South China Normal University, University Town, Guangzhou 510006, China. Electronic address:
PM has a detrimental impact on human health and has become a focus of widespread concern. The tempo-spatial distribution of emerging pollutants has been extensively studied, while there is a scarcity of understanding their vertical distribution in atmospheric environment. Here we investigated the vertical profiles of phthalate esters (PAEs), organophosphate esters (OPEs), neonicotinoids (NEOs), and per-and polyfluorinated substances (PFASs) in PM at ground level (4.
View Article and Find Full Text PDFAnn Agric Environ Med
December 2024
School of Biomedical Engineering and Imaging, Hubei University of Science and Technology, Hubei, China.
Metabolites
December 2024
Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, University of Bisha, Bisha 61922, Saudi Arabia.
TCIPP (tris(1,3-dichloro-2-propyl) phosphate) and TCEP (tris(2-chloroethyl) phosphate) are organophosphate ester flame retardants found in various consumer products, posing significant health and environmental risks through inhalation, ingestion, and dermal exposure. Research reveals these compounds cause oxidative stress, inflammation, endocrine disruption, genotoxicity, neurotoxicity, and potentially hepatotoxicity, nephrotoxicity, cardiotoxicity, developmental, reproductive, and immunotoxicity. This review summarizes the current knowledge on the toxicological mechanisms of TCIPP and TCEP and presents the latest data on their toxicological effects obtained in vitro and in vivo, using omic systems, and on the basis of computational modelling.
View Article and Find Full Text PDFSci Rep
December 2024
Key Laboratory of Urban and Architectural Heritage Conservation, Ministry of Education, School of Architecture, Southeast University, 2# Sipailou, Nanjing, 210096, China.
Lightweight double leaf walls have been extensively employed in assembly and large-space buildings. Due to the complex and varied stud configurations in double leaf walls, accurately and efficiently predicting the sound transmission loss (STL) of such structures poses a significant challenge. To support performance-based design workflows, this paper presents an analytical model based on sound transmission path decoupling, enabling architects to quickly predict the STL of commonly used lightweight double leaf wall types, including wooden, steel, and acoustical stud constructions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!