Environmental factors influencing indoor airborne fungi in students dormitory - a case study in Nakhon Sithammarat, Thailand.

Rocz Panstw Zakl Hig

Centre of Environmental Health and Safety Studies, Faculty of Health Sciences, Universiti Teknologi MARA (UiTM), Selangor, 42300, Malaysia.

Published: September 2023

Background: Indoor airborne fungi are a significant health concern that can cause respiratory symptoms and other health problems. Indoor fungi are influenced by various factors such as meteorological conditions and dwelling characteristics.

Objective: This study aims to evaluate the association between indoor airborne fungi and environmental factors in a student dormitory in southern Thailand.

Material And Methods: The study was conducted at Walailak University in southern Thailand from September toDecember 2020. Air samples were collected from rooms in thirteen dormitories, and the fungal load was determined using the passive air sampling method. The study also measured meteorological parameters and gathered data on occupant behaviors and exposure-related symptoms through a self-administered questionnaire.

Results: In a total of 135 student rooms, the average concentration (mean ± SD) of indoor airborne fungi was 409.72±176.22 CFU/m3, which showed the highest concentration on the first floor. For meteorological parameters, the averages of RH (%), temperature (°C), and CO2 (ppm) were 70.99±2.37, 31.11±0.56 and 413.29±76.72, respectively. The abundance of indoor airborne fungi was positively associated with an increase in RH (β=0.267, 95% CI: 5.288, 34.401) and building height (β=0.269, 95% CI: 16.283, 105.873), with values of 19.845 and 61.078, respectively. Conversely, temperature exhibited a negative effect on indoor airborne fungi (-92.224, β=-0.292, 95% CI: -150.052, -34.396).

Conclusion: The findings highlight the influence of RH, temperature and building height on indoor airborne fungi in the student dormitory. Therefore, effective management strategies are necessary to improve indoor air quality and reduce associated health risks in student dormitories.

Download full-text PDF

Source
http://dx.doi.org/10.32394/rpzh.2023.0273DOI Listing

Publication Analysis

Top Keywords

indoor airborne
28
airborne fungi
28
indoor
9
environmental factors
8
fungi
8
student dormitory
8
meteorological parameters
8
building height
8
airborne
7
factors influencing
4

Similar Publications

Aerosol dynamics in dental clinics: effects of ventilation mode on the mitigation of airborne diseases transmission.

Environ Pollut

January 2025

State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, Sichuan province, China. Electronic address:

Dental operations inherently involve a high risk of airborne cross-infection among medical staff and patients due to the exposure of respiratory secretions, which contain pathogenic microorganisms and typically spread in the form of aerosols. In order to contribute to the understanding of aerosol dynamics during dental operation and efficiently mitigate their dispersion and deposition through appropriate ventilation, 3D numerical simulations and full-scale experimental measurements were performed in this study. The indoor airflow distribution and dynamic aerosol behaviors observed under three optimized ventilation schemes (Scenario I-III) were compared with those observed under the current ventilation system.

View Article and Find Full Text PDF

Unveiling airborne threats: Vertical profiles of multiple emerging pollutants in PM across the urban atmosphere of Southern China.

J Hazard Mater

December 2024

SCNU Environmental Research Institute, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China; School of Environment, South China Normal University, University Town, Guangzhou 510006, China. Electronic address:

PM has a detrimental impact on human health and has become a focus of widespread concern. The tempo-spatial distribution of emerging pollutants has been extensively studied, while there is a scarcity of understanding their vertical distribution in atmospheric environment. Here we investigated the vertical profiles of phthalate esters (PAEs), organophosphate esters (OPEs), neonicotinoids (NEOs), and per-and polyfluorinated substances (PFASs) in PM at ground level (4.

View Article and Find Full Text PDF
Article Synopsis
  • Fungal contamination in hospital air can impact the health of staff, patients, and caregivers, with a study in Wuhan revealing that factors like temperature, humidity, and seasonal changes significantly influence fungal concentration rather than disease type or personnel density.
  • The analysis showed that airborne fungal particle sizes are normally distributed, with the highest proportions found in specific size ranges, but the median diameter remained below 3.19 μm across different departments in both winter and summer.
  • The findings suggest a need for improved filtration efficiency for specific fungal particle sizes and the use of appropriate antifungal treatments and hygiene practices in hospital air management.
View Article and Find Full Text PDF

TCIPP (tris(1,3-dichloro-2-propyl) phosphate) and TCEP (tris(2-chloroethyl) phosphate) are organophosphate ester flame retardants found in various consumer products, posing significant health and environmental risks through inhalation, ingestion, and dermal exposure. Research reveals these compounds cause oxidative stress, inflammation, endocrine disruption, genotoxicity, neurotoxicity, and potentially hepatotoxicity, nephrotoxicity, cardiotoxicity, developmental, reproductive, and immunotoxicity. This review summarizes the current knowledge on the toxicological mechanisms of TCIPP and TCEP and presents the latest data on their toxicological effects obtained in vitro and in vivo, using omic systems, and on the basis of computational modelling.

View Article and Find Full Text PDF

Airborne sound insulation performance of lightweight double leaf walls with different stud types.

Sci Rep

December 2024

Key Laboratory of Urban and Architectural Heritage Conservation, Ministry of Education, School of Architecture, Southeast University, 2# Sipailou, Nanjing, 210096, China.

Lightweight double leaf walls have been extensively employed in assembly and large-space buildings. Due to the complex and varied stud configurations in double leaf walls, accurately and efficiently predicting the sound transmission loss (STL) of such structures poses a significant challenge. To support performance-based design workflows, this paper presents an analytical model based on sound transmission path decoupling, enabling architects to quickly predict the STL of commonly used lightweight double leaf wall types, including wooden, steel, and acoustical stud constructions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!