Using a randomized crossover protocol, 10 young men completed four 180 min exposures (38 °C, 60% relative humidity), alternating between 30 min of walking and 30 min of sitting where fluid or ice slurry were served. Participants underwent four trials: (i) 5 mL·kg body mass of 20 °C water (CON); (ii) 5 mL·kg body mass of 20 °C water + fan at 4 m·s (FAN); (iii) fan + 3 mL·kg body mass of ice slurry + 2 mL·kg body mass of 4 °C water (FAN + ISCW); and (iv) FAN + ISCW + lower-leg immersion in 20 °C water (FAN + ISCW + LLI). Sweat and body mass losses were higher with FAN than CON, FAN + ISCW, and FAN + ISCW + LLI. Mean and peak changes in Δrectal temperature, heart rate, and perceived heat and thirst from baseline were not statistically and practically different between FAN and CON. FAN + ISCW + LLI decreased sweat loss compared with FAN + ISCW and mean and peak changes in Δrectal temperature, heart rate, and perceived thirst compared with CON. FAN + ISCW + LLI also attenuated the changes in Δrectal temperature (peak) and thirst (mean and peak) compared with FAN. In conclusion, FAN slightly exacerbates fluid loss but does not attenuate the changes in Δrectal temperature, heart rate, and perceived heat and thirst during intermittent physical activity in hot-humid conditions. However, coupling ISCW or ISCW + LLI with the use of a fan attenuates the increase in these outcomes compared with no intervention and to a greater extent for rectal temperature and thirst when fan is coupled with ISCW + LLI than when it is used in isolation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1139/apnm-2023-0013 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!