Background: With the increased interest in inter-recti distance measurement using ultrasound imaging in physiotherapy, there is a question of measurement reliability, and the importance of the examiner's experience.
Purpose: The study aimed to investigate the reliability of inter-recti distance measurement in a DICOM viewer software by an experienced radiologist. For the measurement, the radiologist used linea alba images captured by two physiotherapists who were novice examiners.
Methods: Ultrasound images were acquired by two novice examiners on repeated occasions 7 days apart (sessions A and B) in 28 nulliparous women at supraumbilical, umbilical, and infraumbilical locations along linea alba.
Results: Excellent intra-examiner reliability of inter-recti distance measurements was shown at the supraumbilical and umbilical levels (ICC = 0.941-0.983) with minimal detectable change (MDC) ranging from 1.31 mm to 2.29 mm. Infraumbilical measurements had good to excellent reliability (ICC = 0.894-0.972) with MDC ranging from 0.33 mm to 0.72 mm. Session A inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at each location (ICC = 0.913-0.954) with MDC ranging from 0.47 mm to 2.96 mm. Session B inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at the supraumbilical and umbilical (ICC = 0.94-0.98), MDC ranging from 1.38 mm to 2.58 mm and good (ICC ≥ 0.81) with MDC ranging from 0.72 mm to 0.80 mm at the infraumbilical locations.
Conclusion: Novice examiners were able to capture good-quality ultrasound images of the linea alba that allowed for good to excellent intra- and inter-examiner reliability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/09593985.2023.2255897 | DOI Listing |
Sports Health
December 2024
University of Pittsburgh Medical Center Sports Medicine Concussion Program, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania.
Background: Factors associated with performance outside of a normative range on dynamic exertion test (EXiT) after sport-related concussion (SRC) remain unknown. This study examined the role of demographic and medical history factors on performance using minimal detectable change (MDC) cutoff scores in athletes being cleared to return to sport (RTS) from SRC.
Hypothesis: Older age, being female, and body mass index (BMI) ≥50th percentile would be associated with worse EXiT performance and with increased likelihood of falling outside the normative MDC score range.
Int J Mol Sci
November 2024
Department of Biophysics of Environmental Pollution, Faculty of Biology and Environmental Protection, University of Lodz, Pomorska Str. 141/143, 90-236 Lodz, Poland.
The aim of the present study was to investigate the concentration- and size-dependent effects of non-functionalized polystyrene nanoparticles (PS-NPs) of varying diameters (29 nm, 44 nm, and 72 nm) on specific epigenetic modifications and gene expression profiles related to carcinogenesis in human peripheral blood mononuclear cells (PBMCs) in vitro. This in vitro human-cell-based model is used to investigate the epigenetic effect of various environmental xenobiotics. PBMCs were exposed to PS-NPs at concentrations ranging from 0.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
December 2024
Ramsay Santé, Hôpital Privé d'Antony, 1 rue Velpeau, 92160 Antony, France.
Introduction: Patellar instability is a multifactorial pathology requiring precise evaluation of its contributing factors, particularly patella alta. Patellotibial height measurement indexes, such as the Caton-Deschamps index, have the disadvantage of being referenced to the tibia. Patellotrochlear indexes are more appropriate but fail to account for variable knee flexion during magnetic resonance imaging (MRI).
View Article and Find Full Text PDFJ Bodyw Mov Ther
March 2025
Department of Ergonomics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran. Electronic address:
Purpose: Poor performance in practicing balance tasks is partly caused by the changes in the knee function and balance control activities following total knee arthroplasty (TKA). The purpose of this study was to determine the test-retest reliability of the static and dynamic balance measures using Wii Balance Board (WBB) in patients after TKA.
Design: Thirty-one TKA patients (6 males, 27 females, mean age 55 ± 5.
ACS Synth Biol
December 2024
State Key Laboratory of Biocatalysis and Enzyme Engineering, Hubei Key Laboratory of Industrial Biotechnology, Hubei University, Wuhan 430062, Hubei, China.
Hand, foot, and mouth disease (HFMD), caused by enteroviruses, mostly including EV71, CVA6, CVA10, and CVA16, is an acute infectious disease commonly found in children. Due to no approved antiviral therapies and available vaccines, except for EV71, developing accurate diagnostic methods of HFMD is essential for controlling its spread and mitigating its impact on public health. Here, we create a MIRA-HEV-PAND multiple nucleic acid typing method that utilizes Ago to identify enterovirus type A pathogens (EV71, CVA6, CVA10, and CVA16) and universal type EVU.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!