ComBat Harmonization of Myocardial Radiomic Features Sensitive to Cardiac MRI Acquisition Parameters.

Radiol Cardiothorac Imaging

From the Department of Radiology, University of Iowa Carver College of Medicine, 200 Hawkins Dr, Iowa City, IA 52242 (S.P., S.N.); Department of Electrical and Computer Engineering (D.D.D., M.J.) and Department of Biostatistics (E.S., K.D.C.), University of Iowa, Iowa City, Iowa; Department of Radiology, University of Miami, Miller School of Medicine, Miami, Fla (P.Y.A.); and Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wis (P.N.).

Published: August 2023

AI Article Synopsis

  • The study examines how ComBat harmonization methods affect the stability of cardiac MRI-derived radiomic features when imaging parameters change.
  • It involves a retrospective analysis of data from 11 healthy subjects and 5 patients, using various MRI sequences to assess radiomic feature stability.
  • Results show that applying ComBat harmonization significantly enhances the stability of these features, with parametric ComBat achieving 95.1% stability compared to only 51.4% without any harmonization.

Article Abstract

Purpose: To investigate the effect of ComBat harmonization methods on the robustness of cardiac MRI-derived radiomic features to variations in imaging parameters.

Materials And Methods: This Health Insurance Portability and Accountability Act-compliant retrospective study used a publicly available data set of 11 healthy controls (mean age, 33 years ± 16 [SD]; six men) and five patients (mean age, 52 years ± 16; four men). A single midventricular short-axis section was acquired with 3-T MRI using cine balanced steady-state free precision, T1-weighted, T2-weighted, T1 mapping, and T2 mapping imaging sequences. Each sequence was acquired using baseline parameters and after variations in flip angle, spatial resolution, section thickness, and parallel imaging. Image registration was performed for all sequences at a per-individual level. Manual myocardial contouring was performed, and 1652 radiomic features per sequence were extracted using baseline and variations in imaging parameters. Radiomic feature stability to change in imaging parameters was assessed using Cohen sensitivity. The stability of radiomic features was assessed both without and after ComBat harmonization of radiomic features. Three ComBat methods were studied: parametric, nonparametric, and Gaussian mixture model (GMM).

Results: For all sequences combined, 51.4% of features were robust to changes in imaging parameters when no ComBat method was applied. ComBat harmonization substantially increased the number of stable features to 95.1% (95% CI: 94.9, 95.3) when parametric ComBat was used and 90.9% (95% CI: 90.6, 91.2) when nonparametric ComBat was used. GMM combat resulted in only 52.6% stable features.

Conclusion: ComBat harmonization improved the stability of radiomic features to changes in imaging parameters across all cardiac MRI sequences. Cardiac MRI, Radiomics, ComBat, Harmonization © RSNA, 2023.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10483256PMC
http://dx.doi.org/10.1148/ryct.220312DOI Listing

Publication Analysis

Top Keywords

combat harmonization
24
radiomic features
24
imaging parameters
16
cardiac mri
12
combat
11
features
8
variations imaging
8
age years
8
stability radiomic
8
changes imaging
8

Similar Publications

Harmonization for Parkinson's Disease Multi-Dataset T1 MRI Morphometry Classification.

NeuroSci

November 2024

National Institute of Neurological Disorders and Strokes, National Institutes of Health, Bethesda, MD 20892, USA.

Classification of disease and healthy volunteer cohorts provides a useful clinical alternative to traditional group statistics due to individualized, personalized predictions. Classifiers for neurodegenerative disease can be trained on structural MRI morphometry, but require large multi-scanner datasets, introducing confounding batch effects. We test ComBat, a common harmonization model, in an example application to classify subjects with Parkinson's disease from healthy volunteers and identify common pitfalls, including data leakage.

View Article and Find Full Text PDF

Advancing Phage Therapy: A Comprehensive Review of the Safety, Efficacy, and Future Prospects for the Targeted Treatment of Bacterial Infections.

Infect Dis Rep

November 2024

Drug Discovery and Development, Creative Biolabs Inc., Shirley, NY 11967, USA.

Background: Phage therapy, a treatment utilizing bacteriophages to combat bacterial infections, is gaining attention as a promising alternative to antibiotics, particularly for managing antibiotic-resistant bacteria. This study aims to provide a comprehensive review of phage therapy by examining its safety, efficacy, influencing factors, future prospects, and regulatory considerations. The study also seeks to identify strategies for optimizing its application and to propose a systematic framework for its clinical implementation.

View Article and Find Full Text PDF

Rationale And Objectives: To investigate the effect of ComBat harmonization on the stability of myocardial radiomic features derived from multi-energy CT reconstructions.

Materials And Methods: A retrospective study was conducted on 205 patients who underwent dual-energy chest CTA at a single center. The data was reconstructed into multiple spectral reconstructions (mixed energy simulating standard 120 Kv acquisition and monoenergetic images ranging from 40 to 190 keV in increments of 10).

View Article and Find Full Text PDF

The COVID-19 pandemic underscored the critical role of states' regulatory capacities. Countries had to authorize novel vaccine technologies in the context of scientific uncertainty and political pressure, issues particularly acute in middle-income countries (MICs) less familiar with the procedures needed to streamline regulatory processes during a crisis. How did regulatory agencies in countries still building their regulatory capacities expedite the authorization of new COVID-19 vaccines to combat the pandemic? How did they navigate political pressures to expedite vaccine approval while maintaining safety and efficacy standards? We explore these questions through the case of Brazil, which has one of Latin America's most highly-regarded regulatory authorities, but was subject to acute political conflicts.

View Article and Find Full Text PDF

Assessment of ComBat Harmonization Performance on Structural Magnetic Resonance Imaging Measurements.

Hum Brain Mapp

December 2024

Department of Neurosciences and Mental Health, Fondazione IRCS Cà Granda Ospedale Policlinico, Milano, Italy.

Data aggregation across multiple research centers is gaining importance in the context of MRI research, driving diverse high-dimensional datasets to form large-scale heterogeneous sample, increasing statistical power and relevance of machine learning and deep learning algorithm. Site-related effects have been demonstrated to introduce bias in MRI features and confound subsequent analyses. Although Combating Batch (ComBat) technique has been recently reported to successfully harmonize multi-scale neuroimaging features, its performance assessments are still limited and largely based on qualitative visualizations and statistical analyses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!