Introduction: Injury to the posterolateral corner (PLC) of the knee often requires surgical reconstruction. There remains no consensus on treatment for PLC injury, and, therefore, it is imperative to have a reproducible injury model to improve the general knowledge of PLC injuries. A novel cadaveric model of isolated PLC injury is proposed and evaluated using radiographic parameters as well as gross dissection.
Material And Methods: All protocols were reviewed by the Human Investigation and Research Committee of the home institution and were approved. Translational force in a defined posterior and lateral direction was applied to cadaveric native knees to induce PLC injury. Varus and recurvatum stress fluoroscopic imaging was obtained of each specimen before and after the injury model. Lateral joint distance and recurvatum angle after stress was measured on each image via picture archiving and communication software (PACS) imaging software. After the injury model, injured structures were assessed via saline loading and gross dissection. Any specimens found to be fractured were excluded from the analysis of stress radiography.
Results: A total of 12 knees underwent testing and 6/12 successfully induced PLC injury without fracture. The lateral capsule was torn in every specimen. The popliteofibular ligament (PFL) was torn in 83% of specimens and the fibular collateral ligament (FCL) in 66.7% of specimens. The median lateral gapping after injury under varus stress radiography was 5.39 mm and the median recurvatum angle after injury was 14.25°. Radiographic parameters had a direct relationship with a number of structures injured.
Conclusions: This is the first successful cadaver model of PLC injury. The lateral capsule was injured in every specimen emphasizing the importance of this structure to the PLC.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492637 | PMC |
http://dx.doi.org/10.7759/cureus.43287 | DOI Listing |
Adv Wound Care (New Rochelle)
January 2025
Kenatha Scientific Consulting LLC, Fort Worth, Texas, USA.
SN514 is a thermolysin-like enzyme under development as a debrider. Preclinical and non-clinical studies supported a first in human healthy volunteer study to predict the need for protection of periwound skin. Pharmacologic activity testing compared digestion of collagen, fibrin, and elastin with relevant enzymes.
View Article and Find Full Text PDFArch Bone Jt Surg
January 2024
Department of Epidemiology, School of Public Health, Iran University of Medical Sciences, Tehran, Iran.
Objectives: This study aimed to introduce a new arthroscopic method for reconstructing the popliteus tendon (PT). This minimally invasive technique is performed through the posterolateral corner (PLC) of the knee, which can reconstruct the posterolateral rotary instability (PLRI) of the knee.
Methods: Thirty-nine patients (8 females, 31 males) with PLC injury and normal knee alignment underwent arthroscopic PT reconstruction.
Brain Spine
December 2024
Orthopedic Surgery Department, Unidade Local de Saúde de Braga, Portugal - Sete Fontes, São Victor, 4710-243, Braga, Portugal.
Introduction: Thoracolumbar (TL) transition trauma is frequent and challenging. Although short- (SSPF) and long-segment posterior fixation (LSPF) are its mainstay treatment, little is known about their failure rates and reasons behind it.
Research Question: understand why TL instrumentations fail and what factors influence it.
Introduction: Fibular- and tibiofibular-based reconstructions are the gold standard treatment for posterolateral corner (PLC) injuries of the knee. This is the first report describing a wholly tibial-based PLC reconstruction.
Case Report: A 50-year-old female presented with knee instability following proximal fibular resection for a benign tumor, associated with chronic anterior cruciate ligament (ACL) deficiency from a previous injury.
Polymers (Basel)
December 2024
Department of Mechanical Engineering, Hanyang University ERICA, 55, Hanyangdaehak-ro, Sangnok-gu, Ansan-si 15588, Gyeonggi-do, Republic of Korea.
This study focuses on an equivalent model of Polyvinyl Butyral (PVB) laminated glass to simulate the Head Injury Criterion (HIC) when a pedestrian collides with a TRAM. To simulate the collision behavior that occurs when a pedestrian's head collides with PVB laminated glass, a comparison was made between the results of the widely used PLC model for PVB laminated glass modeling and an actual dynamic head impact test. The material properties of the tempered glass and PVB film used in the PLC and equivalent models were obtained via four-point bending tests and tensile tests, respectively.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!