A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of an analytical method for indoor polycyclic aromatic hydrocarbons and their halogenated derivatives by using thermal separation probe coupled to gas chromatography-tandem mass spectrometry. | LitMetric

Polycyclic aromatic hydrocarbons (PAHs) and their halogenated derivatives (XPAHs) have been a concern because of their high toxicity. Monitoring indoor PAHs and XPAHs concentrations is important for risk assessment because humans typically spend >90 % of their time indoors. However, the background levels of indoor PAHs and XPAHs concentrations are unknown because of the low sensitivity of conventional analytical methods. In this study, we developed a highly sensitive analytical method using a thermal separation probe (TSP) coupled to a gas chromatograph with a triple quadrupole mass spectrometer method for 26 PAHs and 40 XPAHs. The method quantification limit (MQL) values of the TSP method were 1.1 (3,8-dichlorofluoranthene)-906 (dibenzo[a,e]pyrene) times lower than those of the conventional method. The regression line comparing the TSP and conventional methods was y = (0.944 ± 0.0401)x, which was in good agreement. These results demonstrate that the TSP method can be applied to indoor air analysis. The total concentrations of PAHs and XPAHs were 944 and 73.5 pg m for the house and 735 and 0.924 pg m in the office, respectively. Among the detected compounds, 13 PAHs and XPAHs could not be detected using conventional methods because of their high MQL values. The composition of total toxicity equivalency values in the house was dominated by dibenzo[a,i]pyrene (DBaiP: 43.2 %) and dibenzo[a,h]pyrene (DBahP: 27.1 %), which could not be detected using the conventional method. Therefore, the TSP method can improve the risk assessment of indoor PAHs and XPAHs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2023.166931DOI Listing

Publication Analysis

Top Keywords

pahs xpahs
24
indoor pahs
12
tsp method
12
method
9
analytical method
8
polycyclic aromatic
8
aromatic hydrocarbons
8
halogenated derivatives
8
thermal separation
8
separation probe
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!