A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantification of cardiac pumping mechanics in TAVI patients: A pilot study utilizing minimally invasive method for pressure-volume analysis. | LitMetric

The ventriculo-arterial coupling (VAC) and left ventricle (LV) mechanics are crucial and play an important role in the pathophysiology of aortic stenosis (AS). The pressure-volume (PV) analysis is a powerful tool to study VAC and LV mechanics. We proposed a novel minimally-invasive method for PV analysis in patients with severe AS receiving transcatheter aortic valve implantation (TAVI). Patients with severe AS were prospectively enrolled in a single center. LV pressure and cardiac output were recorded before and after TAVI. We constructed the PV loop for analysis by analyzing LV pressure and the assumed flow. 26 patients were included for final analysis. The effective arterial elastance (Ea) decreased after TAVI (3.7 ± 1.3 vs. 2.9 ± 1.1 mmHg/mL, p < 0.0001). The LV end-systolic elastance (Ees) did not change immediately after TAVI (2.4 ± 1.3 vs. 2.6 ± 1.1 mmHg/mL, p = 0.3670). The Ea/Ees improved after TAVI (1.8 ± 0.8 vs. 1.2 ± 0.4, p < 0.0001), demonstrating an immediate improvement of VAC. The stroke work (SW) did not change (7669.6 ± 1913.8 vs. 7626.2 ± 2546.9, p = 0.9330), but the pressure-volume area (PVA) decreased (14469.0 ± 4974.1 vs. 12177.4 ± 4499.9, p = 0.0374) after TAVI. The SW/PVA increased after TAVI (0.55 ± 0.12 vs. 0.63 ± 0.08, p < 0.0001) representing an improvement of LV efficiency. We proposed a novel minimally invasive method for PV analysis in patients with severe AS receiving TAVI. The VAC and LV efficiency improved immediately after TAVI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492004PMC
http://dx.doi.org/10.14814/phy2.15799DOI Listing

Publication Analysis

Top Keywords

tavi patients
8
pressure-volume analysis
8
patients severe
8
analysis
5
quantification cardiac
4
cardiac pumping
4
pumping mechanics
4
tavi
4
mechanics tavi
4
patients
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!