Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
(1) Background: Synthetic CT images of the pelvis were generated from daily CBCT images to monitor changes in water equivalent path length (WEPL) and determine the dosimetric impact of anatomy changes along the proton beam's path; (2) Methods: Ten pediatric patients with pelvic tumors treated using proton therapy with daily CBCT were included. The original planning CT was deformed to the same-day CBCT to generate synthetic CT images for WEPL comparison and dosimetric evaluation; (3) Results: WEPL changes of 20 proton fields at the distal edge of the CTV ranged from 0.1 to 12 mm with a median of 2.5 mm, and 75th percentile of 5.1 mm for (the original CT-rescanned CT) and ranged from 0.3 to 10.1 mm with a median of 2.45 mm and 75th percentile of 4.8 mm for (the original CT-synthetic CT). The dosimetric impact was due to proton range pullback or overshoot, which led to reduced coverage in CTV Dmin averaging 12.1% and 11.3% in the rescanned and synthetic CT verification plans, respectively; (4) Conclusions: The study demonstrated that synthetic CT generated by deforming the original planning CT to daily CBCT can be used to quantify proton range changes and predict adverse dosimetric scenarios without the need for excessive rescanned CT scans during large interfractional variations in adaptive proton therapy of pediatric pelvic tumors.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10486424 | PMC |
http://dx.doi.org/10.3390/cancers15174200 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!