Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: It is well established that nanotopography and wettability of implant surfaces contribute to osseointegration and long-term implant success. However, the effects of a hydrogenated surface with nanotubular and superhydrophilic properties on peri-implant soft tissue remain unclear. This study was designed to study the impact of a modified abutment surface on early soft tissue integration compared with a machined surface.
Methods: Thirty-six implants were placed at the bone level in the bilateral mandible of six beagles, followed by healing abutments belonging to the standard machined Ti-6Al-4V alloy abutments (TC4-M), anodized abutments with nanotubes (TC4-Nano), and hydrogenated abutments (TC4-H/Nano) groups, which were randomly screwed to the implants. After two and four weeks of wound healing, the animals were euthanized for histological evaluation.
Results: A superhydrophilic nanotubular surface developed on the hydrogenated abutment. Histological and histometric analyses revealed similar peri-implant soft tissue healing and dimensions for the three types of abutments at two and four weeks. Connective tissue (CT) length was longer around TC4-H/Nano abutments compared with standard abutments; however, the differences were not statistically significant. Moreover, collagen fibers in the TC4-H/Nano group extended and were attached perpendicularly to the superhydrophilic surface.
Conclusions: Our results revealed that the soft tissue interface adjacent to the hydrogenated abutment is comparable to that of the machined abutment. A tendency of increased CT length and perpendicular collagen fibers was observed around the modified abutment. This study suggests that nanotubular/superhydrophilic surfaces could be a promising modification to enhance soft tissue sealing. However, comprehensive studies should be conducted to evaluate the peri-implant soft tissue around the modified abutment immunohistochemically, histopathologically, and clinically.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492342 | PMC |
http://dx.doi.org/10.1186/s12903-023-03347-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!