A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of Kennedy class and number of implants on the accuracy of dynamic implant navigation: An in vitro study using an X-ray free evaluation methodology. | LitMetric

Objectives: The aim of this in vitro study was to evaluate the accuracy of fully guided dynamic implant navigation surgery in Kennedy I, II, and III class dental arch defects with two different implant designs, using an X-ray free evaluation method.

Methods: Polyurethane resin maxillary models simulated posterior edentulous defects. Four cone beam computed tomography (CBCT) scans and four intraoral (IOS) scans were obtained for each model and a digital wax-up with the correct implant positions was made. The accuracy of implant positions was evaluated using an IOS-based X-ray-free method (3Shape). Four deviation characteristics were evaluated: insertion point, depth deviation, horizontal and angle deviation.

Results: The insertion point deviation measures ranged from 0.19 mm to 1.71 mm. Depth (s) and (u) deviations ranged from -1.47 mm to 0.74 mm and from 0.02 mm to 1.47 mm, respectively. Horizontal deviation ranged from 0.09 mm to 1.37 mm.

Conclusions: There is a tendency of a decreasing insertion point deviation for an increasing number and distribution area of the teeth (increasing Kennedy class number). Kennedy class II and distal implant position had the most influence for the higher deviations.

Clinical Significance: Dynamic implant guidance provides accurate spacing, angulation, depth and position of the implants. It is important to understand how the number of missing teeth and implant design could influence the accuracy of dynamic implant navigation. Thus, it is important to evaluate factors influencing the accuracy of dynamic systems by using a X-ray-free post-operative method and to overcome the limitations of providing multiple CBCT scans.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2023.104679DOI Listing

Publication Analysis

Top Keywords

dynamic implant
16
kennedy class
12
accuracy dynamic
12
implant navigation
12
insertion point
12
implant
9
class number
8
vitro study
8
x-ray free
8
free evaluation
8

Similar Publications