Background: Computer-assisted surgery is used to design and manufacture cutting guides in mandibular reconstructions with fibula-free flaps. To improve the outcomes of the procedure, the aim of this research was to investigate and compare the accuracy of mandibular reconstruction following the use of 2 versus 3 anatomical reference cutting guides.

Methods: Eighteen sets of prototype bone models retrieved from an ameloblastoma patient were used for mock operations. The mandibular segmental osteotomies and fibular reconstructions were performed using 2 and 3 anatomical reference cutting guides in vivo surgeries. After reconstruction, the accuracy of the placed reference points was measured by superimposition of computed tomography images.

Results: The error in cutting guides when using 2 or 3 anatomical references showed no significant difference. The fibular and condylar errors of the cutting guide between 2 and 3 anatomical references showed no significant difference in every plate type. The difference in screw hole position errors between 2 and 3 anatomical reference cutting guides was not statistically significant.

Conclusions: Two anatomical reference cutting guides are sufficient and reasonable enough for mandible resection. However, there were some limitations and errors in our study.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000009740DOI Listing

Publication Analysis

Top Keywords

cutting guides
20
anatomical reference
16
reference cutting
16
anatomical references
12
cutting
8
cutting guide
8
references difference
8
anatomical
7
guides
5
reference
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!