Background: The use of cementless femoral stems in patients undergoing primary total hip arthroplasty (THA) with Dorr C bone remains controversial for fear of fracture or subsidence. Purpose of this multicenter study was to compare clinical outcomes and complications of THA using a tapered femoral prosthesis in patients with Dorr C bone versus Dorr A/B bone.

Methods: A total of 1,030 patients underwent primary THA with a tapered wedge femoral stem at a minimum one year follow up. Forty-eight patients with Dorr C bone (mean age 68.7 years) were compared with a matched cohort of patients with Dorr A/B bone (mean age 69.9 years). Mean follow-up was approximately 4 years in both cohorts. There were no differences in sex, age, body mass index (BMI), Harris Hip Score (HHS), complications, and radiographic outcomes including subsidence and aseptic loosening were evaluated.

Results: Postoperative HHSs were a mean of 82 points in the Dorr C cohort compared to 84 points in the Door A/B cohort (P=0.2653). There was no significant difference in complication or revision rates for any reason (P=0.23). Mean subsidence for the Dorr C and Dorr A/B was 1.4 and 1.2 mm, respectively (P=0.5164), and there was no aseptic loosening of the femoral component found in either group.

Conclusions: Current generation tapered wedge cementless femoral stems provide stable fixation for patients with Dorr C bone quality without increased complications with respect to fracture or subsidence and can be considered an alternative to cemented stems in patients with compromised bone quality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10477656PMC
http://dx.doi.org/10.21037/atm.2019.08.124DOI Listing

Publication Analysis

Top Keywords

dorr bone
16
patients dorr
16
tapered wedge
12
stems patients
12
dorr a/b
12
dorr
10
patients
8
patients undergoing
8
undergoing primary
8
primary total
8

Similar Publications

Effectiveness of the Dorr index in predicting implant failure before proximal femoral nail application.

Jt Dis Relat Surg

January 2025

Dr. Abdurrahman Yurtaslan Ankara Onkoloji Eğitim ve Araştırma Hastanesi, Ortopedi ve Travmatoloji Kliniği, 06200 Yenimahalle, Ankara, Türkiye.

Objectives: This study aimed to investigate the importance of the Dorr index in the preoperative evaluation of implant failure in patients who underwent proximal femoral nail (PFN).

Patients And Methods: This retrospective study examined 312 patients who underwent PFN for intertrochanteric fractures between January 2016 and January 2020. Patients with unstable fractures according to the AO/OTA (AO Foundation/Orthopaedic Trauma Association) classification, those over 65 years of age, with at least one year of regular follow-up, a tip-apex distance <25 mm, and a caput-collum-diaphyseal angle between 125° and 135°, were included.

View Article and Find Full Text PDF

Introduction: Short cementless stems offer advantages such as bone-stock preservation and minimally invasive insertion. Despite encouraging short- to midterm outcomes, the long-term clinical and radiological implications of short, titanium, and porous plasma-sprayed flat-tapered stems remain unclear.

Materials And Methods: A retrospective review of 138 primary total hip arthroplasties, conducted between 2010 and 2015 in 130 patients, with a minimum 8-year follow-up was performed.

View Article and Find Full Text PDF

The indication for femoral stem cementation should be made on a patient-specific basis, taking physical activity, femoral geometry, and bone tissue quality into account. Age alone should not be the sole justification for cementation. The Dorr classification can serve as decision support for whether a cemented fixation should be used.

View Article and Find Full Text PDF

Introduction: The comparison between the cementless taper wedge stem and fit-and-fill stem in total hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly assessed. This study aimed to compare the risk of leg length discrepancy (LLD) ≥ 10 mm between these two stem types in Dorr type A, B, and C femurs.

Materials And Methods: From April 2015 through April 2021, we analyzed 1178 unilateral primary cementless THA procedures.

View Article and Find Full Text PDF

Backgroud: In total hip arthroplasty (THA), the ideal stem length remains uncertain; different stem lengths are used in different cases or institutions. We aimed to compare the stress distributions of cementless tapered wedges and short stems in femurs with different femoral marrow geometries and determine the appropriate fit.

Methods: Finite element models were created and analyzed using HyperMesh and LS-DYNA R11.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!