A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A method to detect fulvestrant interference in estradiol in breast cancer patients. | LitMetric

A method to detect fulvestrant interference in estradiol in breast cancer patients.

Endocr Connect

Department of Clinical Pathology, Instituto Português de Oncologia de Lisboa Francisco Gentil, Lisboa, Portugal.

Published: November 2023

Background: Fulvestrant resembles estradiol in its structure. Reports have been published concerning fulvestrant measured as estradiol by the immunoassays. This may induce falsely elevated estradiol results and wrongly impact medical decisions. Our aim was to confirm the interference of fulvestrant on estradiol concentration and test a method to identify the false results.

Methods: Four serum samples with low estradiol levels were spiked with fulvestrant at various concentrations. Estradiol was then measured directly on serum (Dir), after a 1:5 dilution (Dil), and a ratio Dil/Dir was estimated. On the second part of the study, estradiol results (Dir, Dil and ratio Dil/Dir) from 14 women treated with fulvestrant were analysed, as well as from 14 patients not under this treatment.

Results: The addition of exogenous fulvestrant to the serum samples induced a gradual rise on estradiol concentration with a mean ratio for the Dil/Dir samples of 2.1 ± 0.4 (range 1.7-2.9). Patients on fulvestrant treatment experienced a mean ratio for the Dil/Dir estradiol sample of 2.4 ± 0.4 (range 1.6-3.0). In the control group, a mean estradiol ratio Dil/Dir of 1.1 ± 0.1 was observed (range 0.8-1.3). No correlation between the number of days after fulvestrant injection and estradiol result (r = 0.531) was observed.

Conclusion: Our study confirmed the interference of fulvestrant in the estradiol measurement by immunoassay. When fulvestrant was present, the estradiol ratio for Dil/Dir sample was about 2. In the control group, the ratio was around 1. The estradiol Dil/Dir ratio is a simple tool which can be used to identify fulvestrant false immunoassay estradiol results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563597PMC
http://dx.doi.org/10.1530/EC-23-0178DOI Listing

Publication Analysis

Top Keywords

ratio dil/dir
24
estradiol
16
fulvestrant
12
fulvestrant estradiol
12
interference fulvestrant
8
estradiol concentration
8
serum samples
8
ratio
8
dil ratio
8
control group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!