A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Examination and reliability of measuring muscle strength of ankle plantar flexion with knee extended. | LitMetric

[Purpose] A hand-held dynamometer (HHD) is less expensive than the isokinetic muscle strength measurement device, and research using HHD is gradually increasing. However, measurement is performed only at a low muscle strength level at which the heel does not take off or heel detachment occurs; therefore, fixation of the foot becomes a problem. This study aimed to determine the validation of measuring ankle plantar flexion strength (with the knee extended) using HHD. [Participants and Methods] Twenty healthy adults (14 males and 6 females) participated in this study. The chair used in this study was for swallowing videofluorography, which was fixed to a wall bar by the belt. The sensor was located at the third metatarsal head. After warming up, the participants sat in a long sitting position on the chair. We conducted the test two times. We used intraclass correlation coefficient (ICC) and Bland-Altman analysis to assess reliability. [Results] The ICC(1, 1) and ICC(2, 1) results were all greater than 0.9. No fixed and proportional errors were present. [Conclusion] The measurement method of this study was both intra- and inter-examiner reliabilities, which were high, and we suggest that sufficient clinical application is possible.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10475641PMC
http://dx.doi.org/10.1589/jpts.35.619DOI Listing

Publication Analysis

Top Keywords

muscle strength
12
ankle plantar
8
plantar flexion
8
knee extended
8
examination reliability
4
reliability measuring
4
measuring muscle
4
strength
4
strength ankle
4
flexion knee
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!