A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Non-invasive monitoring of cardiac contractility: Trans-radial electrical bioimpedance velocimetry (TREV). | LitMetric

We describe methods and software resources for a bioimpedance measurement technique, 'trans-radial electrical bioimpedance velocimetry' (TREV) that allows for the non-invasive monitoring of relative cardiac contractility and stroke volume. After reviewing the relationship between the measurement and cardiac contractility, we describe the general recording methodology, which requires impedance measurements of the forearm. We provide open-source Jupyter-based software (operable on most computers) for deriving cardiac contractility from the impedance measurements. The software includes tools for removing variance associated with heart rate and respiration. We demonstrate the ability of this bioimpedance measurement for tracking beat-to-beat changes of contractility in a maximal grip force production task. Critically, the results demonstrate both a reactive increase in contractility with force production, and suggest there is a learned increase in contractility prior to grip onset, consistent with anticipatory allostatic autonomic regulation mediated by sympathetic inotropy. The method and software should be of broad utility for investigations of event-related cardiac dynamics in psychophysical studies.

Download full-text PDF

Source
http://dx.doi.org/10.1111/psyp.14411DOI Listing

Publication Analysis

Top Keywords

cardiac contractility
16
non-invasive monitoring
8
electrical bioimpedance
8
bioimpedance measurement
8
impedance measurements
8
force production
8
increase contractility
8
contractility
7
cardiac
5
monitoring cardiac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!