AI Article Synopsis

  • This study evaluated the necessity of monitoring post-filter ionized calcium (pfCa) during regional citrate anticoagulation in continuous renal replacement therapy (RCA-CRRT) for critically ill patients, aiming to reduce costs and workload through potentially decreased monitoring frequency.* -
  • Conducted as a non-inferiority randomized controlled trial in Thailand, the study compared standard pfCa monitoring with a no-monitoring approach, keeping citrate infusion at a predetermined level irrespective of pfCa measurements.* -
  • Results indicated that the filter lifespan was similar between both groups, with no significant difference, suggesting that routine pfCa monitoring may not be required, thus supporting the feasibility of reduced monitoring during RCA-CRRT.*

Article Abstract

Background: Current guidelines recommend monitoring of post-filter ionized calcium (pfCa) when using regional citrate anticoagulation during continuous renal replacement therapy (RCA-CRRT) to determine citrate efficiency for the prevention of filter clotting. However, the reliability of pfCa raises the question of whether routine monitoring is required. Reducing the frequency of pfCa monitoring could potentially reduce costs and workload. Our objective was to test the efficacy and safety of no pfCa monitoring among critically ill patients receiving RCA-CRRT.

Methods: This study was a non-inferiority randomized controlled trial conducted between January 2021 and October 2021 at King Chulalongkorn Memorial Hospital, Thailand. Critically ill patients who were treated with RCA-CRRT were randomized to receive either standard pfCa monitoring (aiming pfCa level of 0.25-0.35 mmol/L), or no pfCa monitoring, in which a constant rate of citrate infusion was maintained at pre-determined citrate concentrations of 4 mmol/L with blinding of pfCa levels to treating clinicians. The primary outcome was the filter lifespan. Non-inferiority would be demonstrated if the upper limit of the 95% confidence interval (CI) for the difference in filter lifespan between the groups was less than 20 h.

Results: Fifty patients were randomized to the standard pfCa monitoring group ( = 25) or no pfCa monitoring group ( = 25). The mean filter lifespan was 54 ± 20 h in the standard pfCa monitoring group and 47 ± 23 h in the no pfCa monitoring group (absolute difference 7.1 h; 95% CI -5.3, 19.5,  = .25). When restricting the analysis to circuits reaching the maximum duration of circuit lifespan at 72 h and clotted filters, the filter lifespan was 61 ± 17 h in the standard pfCa group vs 60 ± 19 h in the no pfCa monitoring group (absolute difference 0.9 h; 95% CI -11.5, 13.4,  = .88). Compared with the no pfCa monitoring group, the standard pfCa monitoring group had a significantly higher mean citrate concentrations (4.43 ± 0.32 vs 4 mmol/L, < .001) and a higher rate of severe hypocalcemia (44% vs 20%,  = .13). No statistical differences were found in filter clotting, citrate accumulation, citrate overload and mortality between the two groups.

Conclusions: Among critically ill patients receiving RCA-CRRT, no pfCa monitoring by maintaining the citrate concentrations of 4 mmol/L is feasible. Larger randomized controlled trials should be conducted to ensure the efficacy, safety and cost-effectiveness of this strategy.

Trial Registration: ClinicalTrials.gov: NCT04792424 (registered 11 March 2021).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10468745PMC
http://dx.doi.org/10.1093/ckj/sfad069DOI Listing

Publication Analysis

Top Keywords

pfca monitoring
44
monitoring group
28
standard pfca
20
pfca
16
filter lifespan
16
monitoring
14
post-filter ionized
8
ionized calcium
8
regional citrate
8
citrate anticoagulation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!