Background: Add-on devices with projections, e.g., Endocuff, Endocuff Vision, EndoRings, and Wingcap, placed on the distal tip of the colonoscope promise to improve the detection of precancerous lesions. We performed a meta-analysis to evaluate the performance of these devices exclusively among individuals undergoing colonoscopy for screening purpose.

Methods: A computerized literature search was performed across MEDLINE and Cochrane Library databases for randomized controlled trials that compared standard colonoscopy (SC) to procedures using add-on devices. The primary outcome was adenoma detection rate (ADR), while secondary outcomes included polyp detection rate (PDR), advanced ADR (AADR), and sessile serrated lesion detection rate (SSLDR). The effect size on study outcomes was calculated using a random-effects model and presented as the risk ratio (RR) and 95% confidence interval (CI).

Results: Seven studies enrolling a total of 5785 patients were included. The use of add-on-devices with projections was associated with a higher ADR compared to SC: 45.9% vs. 41.1%; RR 1.18, 95%CI 1.02-1.37; P=0.03; =79%. Although PDR was higher in screening colonoscopies assisted by add-on devices as compared to SC, the difference failed to reach significance: 55.1% vs. 50.8%; RR 1.10, 95%CI 0.96-1.26; P=0.17; =75%. No difference was found between procedures assisted by add-on devices with projections and SC colonoscopies in terms of AADR (18.5% vs. 17.6%; RR 1.00, 95%CI 0.79-1.27; P=0.98; =56%) or SSLDR (6.8% vs. 5.8%; RR 1.17, 95%CI 0.95-1.44; P=0.15; =0%).

Conclusion: Colonoscopy assisted by add-on devices with projections achieves a better ADR compared to SC among individuals undergoing screening for bowel cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10433254PMC
http://dx.doi.org/10.20524/aog.2023.0820DOI Listing

Publication Analysis

Top Keywords

add-on devices
24
devices projections
16
detection rate
12
assisted add-on
12
individuals undergoing
8
adr compared
8
add-on
6
devices
6
projections
5
screening
4

Similar Publications

Biological applications using multiphoton microscopy increasingly seek a larger field of view while maintaining sufficient temporal sampling to observe dynamic biological processes. Multiphoton imaging also requires high numerical aperture microscope objectives to realize efficient non-linear excitation and collection of fluorescence. This combination of low-magnification and high-numerical aperture poses a challenge for system design.

View Article and Find Full Text PDF

Background: The Centers for Medicare and Medicaid Services (CMS) New Technology Add-on Payment (NTAP) program supports adoption of new, costly medical technologies demonstrating substantial clinical improvement. In 2021, CMS waived the "substantial clinical improvement" criterion for devices designated under the FDA Breakthrough Devices Program (BDP). This study characterized risk-standardized payments associated with hospitalizations in which Medicare beneficiaries received calcium modification during PCI for acute myocardial infarction (AMI) following the adoption of the Shockwave C Coronary Intravascular Lithotripsy (IVL) Catheter (Shockwave Medical) with BDP designation.

View Article and Find Full Text PDF

Background: Non-invasive approach other than conventional endoscopy could be effectively used for screening and monitoring esophageal variceal bleeding (EVB).

Purpose: To retrospectively investigate the role of four-dimensional (4D) flow magnetic resonance imaging (MRI) as an add-on tool to endoscopy for predicting EVB in cirrhotic patients with esophageal varices (EVs).

Material And Methods: A cohort of 109 cirrhotic patients with EVs was divided into four groups: A = negative red color [RC] sign, no EVB, n = 60; B = negative RC sign, EVB, n = 13; C = positive RC sign, no EVB, n = 10; and D = positive RC sign, EVB, n = 26.

View Article and Find Full Text PDF

Fluorescence lifetime imaging in drug delivery research.

Adv Drug Deliv Rev

January 2025

Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry, Russian Academy of Sciences, 117997, Moscow, Russia; School of Mathematical and Physical Sciences, Faculty of Science and Engineering, Macquarie University, Sydney, NSW 2109, Australia; Research Center for Translational Medicine, Sirius University of Science and Technology, 354340, Sochi, Russia; National Research Ogarev Mordovia State University, Saransk, Mordovia Republic 430005, Russia.

Once an exotic add-on to fluorescence microscopy for life science research, fluorescence lifetime imaging (FLIm) has become a powerful and increasingly utilised technique owing to its self-calibration nature, which affords superior quantification over conventional steady-state fluorescence imaging. This review focuses on the state-of-the-art implementation of FLIm related to the formulation, release, dosage, and mechanism of action of drugs aimed for innovative diagnostics and therapy. Quantitative measurements using FLIm have appeared instrumental for encapsulated drug delivery design, pharmacokinetics and pharmacodynamics, pathological investigations, early disease diagnosis, and evaluation of therapeutic efficacy.

View Article and Find Full Text PDF

We present a implementation method of light-sheet microscopy utilizing a highly miniaturized device that produces light-sheet illumination while immersed in the sample container. Our miniaturized plane illuminator (MPI) internally equips a two-axis beam-scanning mechanism based on a magnetostatically driven optical fiber cantilever. A light sheet is produced by fast scanning of the focused beam in an axis while the illumination plane can move in the other axis for positioning and 3D imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!