Background: Most interstitial lung diseases (ILDs) manifest with a restrictive ventilatory defect as the common physiologic abnormality. Low carbon monoxide diffusing capacity (Dlco) is considered to be the earliest abnormality on pulmonary function tests (PFTs) in patients with ILD. However, its measurement requires complex and expensive equipment. Our study aimed to assess if high expiratory flows are the earliest PFT abnormality in patients with idiopathic pulmonary fibrosis (IPF) and ILD.
Methods: In a real-world cohort of incident cases with ILD, we identified the initial PFTs on all patients newly diagnosed with ILD at Kingston Health Sciences Center (in Kingston, Ontario, Canada) between 2013 and 2017. The diagnosis of ILD, including IPF, was established as per current guidelines. Among patients with normal forced vital capacity (FVC), total lung capacity (TLC), and Dlco, we assessed the frequency of high expiratory flows defined as forced expiratory volume in 1 s (FEV)/FVC, FEF, FEF, FEF and peak expiratory flow > 95% confidence limit of normal. We adjusted for emphysema, increased airway resistance, and obesity.
Results: We assessed PFTs of 289 patients with ILD; 88 (30%) of them had normal FVC, TLC, and Dlco. Among these, high FEV1/FVC was the most common abnormality in 37% of patients, in 43% of nonobese patients, and in 58% of those with no emphysema and normal airway resistance. Results were similar in the 88 patients with IPF.
Conclusions: High FEV1/FVC could allow identifying patients with ILD/IPF in the earliest stages of their disease with simple spirometry, leading to earlier diagnosis and treatment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10473059 | PMC |
http://dx.doi.org/10.4103/atm.atm_38_23 | DOI Listing |
Int J Pharm
January 2025
School of Mechanical and Mechatronic Engineering, University of Technology Sydney (UTS), 15 Broadway, Ultimo, New South Wales 2007, Australia. Electronic address:
Nanocarrier-based dry powders for lung disease treatment are crucial, with in vitro and in silico research being pivotal to their success. This study introduces a method for creating Tiotropium-bromide liposomal inhalation dry powder, termed "Trojan-particles," utilizing thin-film hydration and spray-drying with lactose-arginine carriers. Encapsulating tiotropium-bromide in nanoliposomes enhances lung treatment via liposomes' unique features.
View Article and Find Full Text PDFJ Family Med Prim Care
December 2024
Vice Chancellor, Atal Bihari Vajpayee Medical University, Lucknow, Uttar Pradesh, India.
Background: It is documented that COVID-19 survivors have prolonged morbidity and functional impairment for many years. Data regarding post-COVID-19 lung functions is lacking from the Indian population. We aim to evaluate the lung functions in such patients after 3-6 months of hospital discharge.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Research Unit of Biomedicine and Internal Medicine, University of Oulu, 902 20 Oulu, Finland.
Mucins 5AC (MUC5AC) and 5B (MUC5B) are the major mucins providing the organizing framework for the airway's mucus gel. We retrieved bronchial mucosal biopsies and bronchial wash (BW) samples through bronchoscopy from patients with chronic obstructive pulmonary disease ( = 38), healthy never-smokers ( = 40), and smokers with normal lung function ( = 40). The expression of MUC5AC and MUC5B was assessed immunohistochemically.
View Article and Find Full Text PDFCureus
November 2024
Department of Anaesthesiology, Sismanogleio General Hospital, Athens, GRC.
The flow-volume loop (FVL) is a valuable yet often underutilized tool for assessing the placement of the laryngeal mask airway (LMA) during surgery. It provides real-time graphical data on airway patency and ventilation. These cases examine the role of FVL in identifying LMA misplacement.
View Article and Find Full Text PDFPediatr Pulmonol
November 2024
Department of Pediatrics, Papé Pediatric Research Institute, Oregon Health & Science University, Portland, Oregon, USA.
Background: Spirometry is the gold standard for assessing airway function for clinical studies; however, obtaining high-quality data in young children remains challenging. Since the forced oscillation technique (FOT) requires less subject cooperations, there has been increasing interest in FOT, particularly in young children. We evaluated whether spirometry and FOT in young children provides comparable ability to detect a treatment effect.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!