Purpose: This study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants.

Materials And Methods: A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured.

Results: While the Primescan (PS) impression group had the highest accuracy with 38 µm, the values of 104 µm and 171 µm were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively ( = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners ( < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values ( > .05).

Conclusion: A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10471506PMC
http://dx.doi.org/10.4047/jap.2023.15.4.179DOI Listing

Publication Analysis

Top Keywords

impression group
16
intraoral scanners
12
group group
12
statistically difference
12
impression groups
12
impression
9
three digital
8
digital intraoral
8
completely edentulous
8
group
8

Similar Publications

Aim: The aim of the present study was to comparatively evaluate the retention of complete dentures and oral health-related quality of life (OHRQoL) of patients with conventional and bioelectric impressions or transcutaneous electric nerve stimulation (TENS).

Materials And Methods: A total of thirty (n = 30) completely edentulous patients were randomly distributed into two groups: Group-C (n = 15) (Conventional) and Group-T (n = 15) (bioelectric). In Group C, border molding was performed using the manual manipulation of borders, and the final impression was made using zinc-oxide eugenol.

View Article and Find Full Text PDF

When Leaders Don't Walk the Walk: A National Survey of Academic Nurse Leader Perceptions of Staff Burnout.

Nurs Educ Perspect

November 2024

About the Authors Adrienne Martinez-Hollingsworth, PhD, MSN, RN, PHN, WAN, is director of research and evaluation, AltaMed Institute for Health Equity, and assistant project scientist, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California. Dawn Goodolf, PhD, RN, is associate dean, Helen S. Breidegam School of Nursing and Public Health, and associate professor, Moravian University, Bethlehem, Pennsylvania. Nia Martin, PhD, MSN, RN, is assistant professor, Loma Linda University School of Nursing, Loma Linda, California. Linda Kim, PhD, RN, PHN, is research scientist, Department of Nursing Research, and assistant professor of medicine, Cedars Sinai Medical Center, Los Angeles, California. Jennifer Saylor, PhD, APRN, ACNS-BC, is associate dean for faculty and student affairs and associate professor, School of Nursing, University of Delaware, Newark, Delaware. Jennifer Evans, DNP, RN, NC-BC, is assistant dean and associate professor, University of Southern Indiana College of Nursing and Health Professions, Evansville, Indiana. Annette Hines, PhD, RN, is the Executive Director of the Susan S. Morrison School of Nursing, University of St. Thomas. Jin Jun, PhD, RN, is assistant professor, Center for Healthy Aging, Self-Management and Complex Care, College of Nursing, Ohio State University, Columbus, Ohio. The first author received a travel stipend from HRSA 22-109 Health and Public Safety Workforce Resiliency Training Program (U3NHP45414).The authors are grateful to Beth Speidel and Delsa Richards for their engagement and feedback. For more information, contact Adrienne Martinez-Hollingsworth at

Aim: This survey explored nurse leaders' impressions of burnout on college/school of nursing (CON/SON) administrative staff and leadership-facilitated strategies used to promote resilience building/mitigate burnout.

Background: Administrative staff are foundational to the success of a university's CON/SON, yet few studies have explored the impact of burnout in this group.

Method: Cross-sectional survey distributed to associate dean and business officer attendees of the 2022 American Association of Colleges of Nursing, Business Officers of Nursing Schools meeting (summer 2022) (n = 64).

View Article and Find Full Text PDF

Objective: To report patient-reported quality-of-life (QOL) outcomes in the DAYLIGHT study.

Study Design: DAYLIGHT was a phase 3b, randomized, double-blind, 24-week, placebo-controlled study. Participants were women aged ≥40 to ≤65 years with moderate to severe vasomotor symptoms (VMS) considered unsuitable for hormone therapy (HT) (contraindications, caution, stoppers, or averse) randomized 1:1 to placebo or fezolinetant 45 mg once daily.

View Article and Find Full Text PDF

Chest pain in a multi-ethnic population: A community-based study on sex differences in chest pain prevalence and care contacts.

Int J Cardiol Cardiovasc Risk Prev

March 2025

Department of Public and Occupational Health, Amsterdam UMC, Location AMC, Amsterdam, the Netherlands.

Objective: While chest pain is a common symptom, its prevalence among women and men across ethnic groups is unknown. Moreover, how chest pain is associated with general practitioner (GP) and cardiologist visits in women and men across ethnic groups, remains to be determined.

Design: We used baseline data on 12423 women and 9071 men from the multi-ethnic HELIUS cohort (Amsterdam, the Netherlands; 2011-2015).

View Article and Find Full Text PDF

BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!