A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simple rules, O-RADS, ADNEX and SRR model: Single oncologic center validation of diagnostic predictive models alone and combined (two-step strategy) to estimate the risk of malignancy in adnexal masses and ovarian tumors. | LitMetric

AI Article Synopsis

  • The study aimed to compare different assessment models for distinguishing between benign and malignant adnexal masses in women, including the ADNEX model, O-RADS, and Simple Rules Risk (SRR).
  • Researchers analyzed data from 514 women between January 2018 and December 2021, measuring sensitivity and specificity of these models, particularly noting the effectiveness of a two-step strategy using Simple Rules followed by either SRR or the ADNEX model for inconclusive cases.
  • Results showed O-RADS had the highest sensitivity, but the combination of Simple Rules and the ADNEX model demonstrated greater overall accuracy and specificity, suggesting this approach is beneficial for clinical evaluations of adnexal masses.

Article Abstract

Objective: To compare performance of Assessment of Different NEoplasias in the adneXa (ADNEX model), Ovarian-Adnexal Reporting and Data System (O-RADS), Simple Rules Risk (SRR) assessment and the two-step strategy based on the application of Simple Rules (SR) followed by SRR and SR followed by ADNEX in the pre-operative discrimination between benign and malignant adnexal masses (AMs).

Methods: We conducted a retrospective study from January-2018 to December-2021 in which consecutive patients with at AMs were recruited. Accuracy metrics included sensitivity (SE) and specificity (SP) with their 95% confidence intervals (CI) were calculated for ADNEX, O-RADS and SRR. When SR was inconclusive a "two-step strategy" was adopted applying SR + ADNEX model and SR + SRR assessment.

Results: A total of 514 women were included, 400 (77.8%) had a benign ovarian tumor and 114 (22.2%) had a malignant tumor. At a threshold malignancy risk of >10%, the SE and SP of ADNEX model, O-RADS and SRR were: 0.92 (95% CI, 0.86-0.96) and 0.88 (95% CI, 0.85-0.91); 0.93 (95% CI, 0.87-0.97) and 0.89 (95% CI, 0.96-0.92); 0.88 (95% CI, 0.80-0.93) and 0.84 (95% CI, 0.80-0.87), respectively. When we applied SR, 109 (21.2%) cases resulted inconclusive. The SE and SP of two-step strategy SR + SRR assessment and SR + ADNEX model were 0.88 (95% CI, 0.80-0.93) and 0.92 (95% CI, 0.89-0.94), SR + ADNEX model 0.90 (95% CI, 0.83-0.95) and 0.93 (95% CI, 0.90-0.96), respectively.

Conclusions: O-RADS presented the highest SE, similar to ADNEX model and SR + ADNEX model. However, the SR + ADNEX model presented the higher performance accuracy with the higher SP and PPV. This two-step strategy, SR and ADNEX model applicated to inconclusive SR, is convenient for clinical evaluation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ygyno.2023.08.012DOI Listing

Publication Analysis

Top Keywords

sr + adnex model
20
two-step strategy
16
adnex model
16
simple rules
12
088 95%
12
95%
11
model
10
adnexal masses
8
o-rads srr
8
092 95%
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!