Introduction: Patients with Paget's disease develop abnormal bony anatomy which can result in significantly altered lower limb alignment predisposing them to early secondary osteoarthritis. Due to the severe extra-articular deformity, total knee arthroplasty (TKA) in these patients is challenging. Conventional knee arthroplasty using intramedullary guides is not an option and can lead to erroneous limb alignment postoperatively. Patient-specific instrumentation (PSI) is a simple solution in such complex primary knee arthroplasty.

Case Report: A 70-year-old male patient presented with a severe left femur deformity and left knee pain. He was diagnosed to have monostotic Paget's disease of the left femur with tricompartmental osteoarthritis of the left knee. After reduction in pathological bone turnover, the patient was planned for a total knee replacement. As a standard intramedullary femoral jig was not applicable due to the femoral deformity, a computed topography-based 3D-printed patient-specific instrument was used. This custom jig was used to define and perform the distal femur cut at 90 degrees to the mechanical axis of the femur in the coronal and sagittal plane. Postoperatively, the patient did well and achieved good function and pain relief.

Conclusion: The use of a 3D-printed PSI for complex primary knee arthroplasty is an excellent option with no additional operative time than a conventional knee arthroplasty. Although a robotic or computer-navigated TKA would be an excellent option in this case, we restored the limb alignment using a cost-effective patient-specific femoral jig. This could be a viable option in centers without navigation or robotic arthroplasty.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10465753PMC
http://dx.doi.org/10.13107/jocr.2023.v13.i08.3826DOI Listing

Publication Analysis

Top Keywords

knee arthroplasty
20
total knee
12
paget's disease
12
femoral jig
12
limb alignment
12
3d-printed patient-specific
8
patient-specific femoral
8
knee
8
conventional knee
8
complex primary
8

Similar Publications

Despite an increasing number of studies examining the effect of Single-Photon Emission Computed Tomography/ Computed Tomography (SPECT/CT) on improvement of diagnosis of aseptic loosening, there is still a great deal of uncertainty regarding its applicability in diagnostic algorithm. Therefore, in this meta-analysis, we aimed to investigate the diagnostic performance of SPECT/CT for identification of aseptic loosening in patients with persistent pain following the total knee arthroplasty (TKA) and total hip arthroplasty (THA). Electronic databases including Medline, Scopus, Web of Science, Cochrane library, and Embase were systematically searched for identifying relevant published studies from their inception to April 2023.

View Article and Find Full Text PDF

The object is to objectively identify the 100 most influential scientific publications in total knee arthroplasty (TKA) and provide an analysis of their main characteristics. The Clarivate Analytics Web of Knowledge database was used to obtain data and metrics of TKA research. The search list was sorted by the number of citations, and articles were included or excluded based on relevance to TKA.

View Article and Find Full Text PDF

The purpose of the present study was to evaluate and compare the clinical outcomes of two groups of patients subject to bi-cruciate retaining (BCR) or posterior-stabilized (PS) implants. It was hypothesized that patients treated with BCR prostheses would present higher flexion and better clinical and functional results than those treated with PS implants. This prospective study included thirty-two patients treated for primary knee osteoarthritis and assigned to two matched groups for their demographic characteristics and comorbidities.

View Article and Find Full Text PDF

This study aimed to evaluate the efficacy of antibiotic-loaded cement articulating spacers produced through a silicone mold in the two-stage revision of infected total knee arthroplasty. Five individuals were prospectively treated with 2-stage revision using spacers made by this mold. Clinical assessment was conducted during and after implantation using the WOMAC Score, Oxford knee score, and range of motion (ROM).

View Article and Find Full Text PDF

Background: This study aims to explore the impact of the National Volume-based Procurement Policy in Guangdong Province on hospitalization costs for total knee arthroplasty inpatients.

Methods: Interrupted time-series analysis were used to examine the expenses associated with total knee arthroplasty for inpatients at a hospital in Guangzhou between May 10, 2021, and December 26, 2023. The period was divided into two phases based on the implementation of the policy, the pre-policy phase (May 10, 2021, to April 30, 2022) and the post-policy phase (May 1, 2022, to December 26, 2023).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!