A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Three-Dimensional Finite Element Analysis of the Stress Distribution Around the Bone Mini-Implant Interface Based on the Mini-Implant Angle of Insertion, Diameter, and Length. | LitMetric

Background: Temporary anchorage devices or mini implants have gained great attraction due to their capability to provide absolute anchorage, low cost, versatility, and can be loaded immediately after placement.

Material And Methods: Finite element analysis was used to evaluate the distribution of stress at the bone mini implant interface based on different angles of insertion (30°, 45°, 60°, and 90°) mini implant diameter (1.3 mm, 1.6 mm, and 2 mm) and mini implant length (6 mm, 8 mm, and 10 mm). A retraction force of 2 N was applied.

Results: Areas of maximum stress concentration were the head and neck of the mini implant and cortical bone around the mini implant. A very minimal amount of stress was found in the cancellous bone. The maximum stress found in the cortical bone was 5.1301 MPa and in the mini implant was 26.355 MPa with an angle of insertion of 30°, a 1.3 mm diameter, and a 6 mm length. The minimum stress found in the cortical bone was 1.4702 MPa and that in the mini implant was 5.3895 MPa with an angle of insertion of 90°, a 2 mm diameter, and a 10 mm length.

Conclusion: For maximum stability, mini implants should be placed at a perpendicular angle of insertion with sufficient diameter and length.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10466509PMC
http://dx.doi.org/10.4103/jpbs.jpbs_524_22DOI Listing

Publication Analysis

Top Keywords

mini implant
28
angle insertion
16
diameter length
12
cortical bone
12
mini
9
finite element
8
element analysis
8
interface based
8
mini implants
8
bone mini
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!