A sensitive and accurate analytical method was developed and validated to detect bambermycin, a commonly used antibiotic in animal feed and livestock. The presence of bambermycin residues in food products can pose health risks to consumers, emphasizing the need for a sensitive and accurate analytical method. A reversed-phase analytical column was utilized with a mobile phase comprising 0.005 mol/L ammonium acetate in 5% acetonitrile (A) and 0.005 mol/L ammonium acetate in 95% acetonitrile (B) to achieve effective chromatographic separation. Quantitative determination of bambermycin in various samples, including beef, pork, chicken, milk, eggs, flatfish, eel, and shrimp, was performed using ultra-high-performance liquid chromatography-tandem mass spectrometry. Sample extraction involved a mixture of methanol and a 25% ammonium hydroxide solution, followed by low-temperature purification and phospholipid removal utilizing a Phree cartridge. The method exhibited a satisfactory recovery rate ranging from 69% to 100%. Validation results demonstrated the reliability, robustness, and accuracy of the method, exhibiting good linearity, precision, and recovery. This validated method can be applied for routine analysis of bambermycin residues, assisting in the development of effective monitoring and control measures to ensure the safety of livestock and aquatic products.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jssc.202300377 | DOI Listing |
Zhongguo Zhong Yao Za Zhi
December 2024
Thirdgrade Pharmacological Laboratory on Traditional Chinese Medicine, State Administration of Traditional Chinese Medicine, China Three Gorges University Yichang 443002, China College of Medicine and Health Sciences, China Three Gorges University Yichang 443002, China.
In this study, the chemical components of Panacis Japonici Rhizoma extract and absorbed components in rats were identified by ultra-high performance liquid chromatography-quadrupole exactive orbitrap mass spectrometry(UPLC-Q-Exactive Orbitrap-MS). The separation was performed by gradient elution on Waters UPLC BEH C_(18) column(2.1 mm×100 mm, 1.
View Article and Find Full Text PDFZhongguo Zhong Yao Za Zhi
December 2024
School of Pharmacy, Shandong University of Traditional Chinese Medicine Ji'nan 250355, China State Key Laboratory of Integration and Innovation of Classic Formula and Modern Chinese Medicine, Lunan Pharmaceutical Group Co., Ltd. Linyi 276005, China.
This study aims to investigate the protective effect and potential mechanism of Jingfang Granules(JF) on the mouse model of chronic fatigue syndrome(CFS). Mice were randomized into normal, model, and low-, medium-, and high-dose(0.9, 1.
View Article and Find Full Text PDFFood Chem
January 2025
School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, People's Republic of China; State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330031, People's Republic of China. Electronic address:
An efficient and rapid ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MSMS) method was developed for simultaneous determination of 5 alternaria toxins (ATs) in edible and medicinal plant - peppermint using MOF-808-trifluoroacetic acid (MOF-808-TFA) as the adsorbent. Characterization methods such as scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and N adsorption-desorption demonstrated that the synthesized MOF-808-TFA had a regular ortho-octahedral configuration and high specific surface area. Under the optimal conditions, the 5 ATs showed good linearity (R ≥ 0.
View Article and Find Full Text PDFFood Chem
January 2025
University of Parma, Department of Chemistry, Life Sciences and Environmental Sustainability, Parco Area delle Scienze 17/A, 43124 Parma, Italy.
The complexity of modern food supply chains limits the effectiveness of targeted approaches to address food traceability issues. Untargeted metabolomics provides a comprehensive profile of small molecules present within biological samples. In this study, the potential of ultra-high performance liquid chromatography-ion mobility-high resolution mass spectrometry (UHPLC-IMS-HRMS) to discriminate bovine milk samples collected at individual level was evaluated for traceability purposes.
View Article and Find Full Text PDFJ Ethnopharmacol
January 2025
College of Pharmacy, Anhui University of Chinese Medicine, Hefei 230012 Anhui, China; Institute of Pharmaceutics, Anhui Academy of Chinese Medicine, Hefei 230012 Anhui, China; MOE-Anhui Joint Collaborative Innovation Center for Quality Improvement of Anhui Genuine Chinese Medicinal Materials, Hefei 230012 Anhui, China; Anhui Engineering Research Center for Quality Improvement and Utilization of Genuine Chinese Medicinal Materials, Hefei 230012 Anhui, China; Center for Xin'an Medicine and Modernization of Traditional Chinese Medicine of IHM, Anhui University of Chinese Medicine, Hefei 230012 Anhui, China. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!