Purpose: Cone-beam computed tomography (CBCT) is widely utilized in modern radiotherapy; however, CBCT images exhibit increased scatter artifacts compared to planning CT (pCT), compromising image quality and limiting further applications. Scatter correction is thus crucial for improving CBCT image quality.

Methods: In this study, we proposed an unsupervised contrastive learning method for CBCT scatter correction. Initially, we transformed low-quality CBCT into high-quality synthetic pCT (spCT) and generated forward projections of CBCT and spCT. By computing the difference between these projections, we obtained a residual image containing image details and scatter artifacts. Image details primarily comprise high-frequency signals, while scatter artifacts consist mainly of low-frequency signals. We extracted the scatter projection signal by applying a low-pass filter to remove image details. The corrected CBCT (cCBCT) projection signal was obtained by subtracting the scatter artifacts projection signal from the original CBCT projection. Finally, we employed the FDK reconstruction algorithm to generate the cCBCT image.

Results: To evaluate cCBCT image quality, we aligned the CBCT and pCT of six patients. In comparison to CBCT, cCBCT maintains anatomical consistency and significantly enhances CT number, spatial homogeneity, and artifact suppression. The mean absolute error (MAE) of the test data decreased from 88.0623 ± 26.6700 HU to 17.5086 ± 3.1785 HU. The MAE of fat regions of interest (ROIs) declined from 370.2980 ± 64.9730 HU to 8.5149 ± 1.8265 HU, and the error between their maximum and minimum CT numbers decreased from 572.7528 HU to 132.4648 HU. The MAE of muscle ROIs reduced from 354.7689 ± 25.0139 HU to 16.4475 ± 3.6812 HU. We also compared our proposed method with several conventional unsupervised synthetic image generation techniques, demonstrating superior performance.

Conclusions: Our approach effectively enhances CBCT image quality and shows promising potential for future clinical adoption.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2023.107377DOI Listing

Publication Analysis

Top Keywords

scatter artifacts
16
scatter correction
12
image quality
12
image details
12
projection signal
12
cbct
11
image
10
contrastive learning
8
scatter
8
cbct image
8

Similar Publications

A Comparison Study of Person Identification Using IR Array Sensors and LiDAR.

Sensors (Basel)

January 2025

Faculty of Science and Technology, Keio University, Yokohama 223-8522, Japan.

Person identification is a critical task in applications such as security and surveillance, requiring reliable systems that perform robustly under diverse conditions. This study evaluates the Vision Transformer (ViT) and ResNet34 models across three modalities-RGB, thermal, and depth-using datasets collected with infrared array sensors and LiDAR sensors in controlled scenarios and varying resolutions (16 × 12 to 640 × 480) to explore their effectiveness in person identification. Preprocessing techniques, including YOLO-based cropping, were employed to improve subject isolation.

View Article and Find Full Text PDF

Resolving Artifacts and Improving the Detection Limit in Circular Differential Scattering Measurement of Chiral and Achiral Gold Nanorods.

ACS Nano

January 2025

Jiangsu Key Laboratory of Frontier Material Physics and Devices, School of Physical Science and Technology, Soochow University, Suzhou, Jiangsu 215006, China.

Circular differential scattering (CDS) spectroscopy has been developed as a powerful method for the characterization of the optical activity of individual plasmonic nanostructures and their complexes with chiral molecules. However, standard measurement setups often result in artifacts that have long raised concerns on the interpretation of spectral data. In fact, the detection limit of CDS setups is constrained by the high level of artifacts, to ±10%.

View Article and Find Full Text PDF

Advancements in Raman light sheet microscopy have provided a powerful, non-invasive, marker-free method for imaging complex 3D biological structures, such as cell cultures and spheroids. By combining 3D tomograms made by Rayleigh scattering, Raman scattering, and fluorescence detection, this modality captures complementary spatial and molecular data, critical for biomedical research, histology, and drug discovery. Despite its capabilities, Raman light sheet microscopy faces inherent limitations, including low signal intensity, high noise levels, and restricted spatial resolution, which impede the visualization of fine subcellular structures.

View Article and Find Full Text PDF

In this paper, we report on the measurement of the optical properties (absorption and scattering coefficients) of photoluminescent turbid media using a homemade integrating sphere setup equipped with a tunable monochromatic light source. The hemispherical reflectance and transmission data are analyzed with the radiative transfer equation using a Monte Carlo simulation-based lookup table to obtain the optical properties of the sample. The results are compared with the optical properties received from a classical integrating sphere setup equipped with a broadband white light source.

View Article and Find Full Text PDF

Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.

Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!