Background: Primary anorectal malignant melanoma (ARMM) is a rare tumor. It is often misdiagnosed as hemorrhoids, polyps or colorectal cancer due to the lack of specificity of their clinical symptoms and imaging manifestations.

Case Presentation: In this study, we reported an 83-year-old female patient with ARMM. Computed tomography (CT) and Magnetic Resonance Imaging (MRI) showed uneven thickening of the intestinal wall about 7.0 cm from the anal margin, and no typical T1 high signal was seen on MRI. Dual-energy spectral CT showed that the effective atomic number (Zeff) of the tumor and the iodine concentration in the arterial phase (AP) and venous phase (VP) were different from other rectal malignancies reported in the previous literature. Sigmoidoscopy showed a large polypoid mass approximately 7.0 cm from the anal verge. Immunohistochemical staining showed that about 60% of Melan A and HMB-45 were positive, S-100 protein and Ki-67 were positive, and the pathological diagnosis was ARMM.

Conclusion: This was the first dual-energy spectral CT imaging report of ARMM. The Zeff and iodine concentration in the arterial phase and venous phase could help distinguish between ARMM and other rectal malignancies.

Download full-text PDF

Source
http://dx.doi.org/10.2174/1573405620666230829150146DOI Listing

Publication Analysis

Top Keywords

dual-energy spectral
12
spectral imaging
8
primary anorectal
8
anorectal malignant
8
malignant melanoma
8
iodine concentration
8
concentration arterial
8
arterial phase
8
phase venous
8
venous phase
8

Similar Publications

Objective: To explore the application of low-energy image in dual-energy spectral CT (DEsCT) combined with deep learning image reconstruction (DLIR) to improve inferior vena cava imaging.

Materials And Methods: Thirty patients with inferior vena cava syndrome underwent contrast-enhanced upper abdominal CT with routine dose, and the 40, 50, 60, 70, and 80 keV images in the delayed phase were first reconstructed with the ASiR-V40% algorithm. Image quality was evaluated both quantitatively [CT value, SD, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for inferior vena cava] and qualitatively to select an optimal energy level with the best image quality.

View Article and Find Full Text PDF

Rationale: Thrombus is the most common occupying lesion in the cardiac chambers, it is often distinguished from cardiac neoplastic occupations. Among them, the most common is cardiac myxoma, whose imaging manifestations are often confused with thrombus. However, the 2 types of lesions have different therapeutic strategies and are both potentially high-risk sources of embolism, so early differentiation between intracardiac thrombus and cardiac tumor is essential.

View Article and Find Full Text PDF

Aims To evaluate the utility of unenhanced spectral imaging, electron density (ED) and overlay electron density (OED) images for assessing pulmonary embolisms in patients with suspected or confirmed acute pulmonary embolism (APE). Background Multiple spectral images can be extrapolated from spectral detector CT (SDCT), ED and OED images. ED and OED images are highly sensitive to moisture-rich tissues.

View Article and Find Full Text PDF

Background: Lung adenocarcinoma (LUAD) is a sub-type of non-small cell lung cancer (NSCLC) that is often associated with genetic alterations, including the Kirsten rat sarcoma viral oncogene homolog () mutation. The mutation is particularly challenging to treat due to resistance to targeted therapies. This study aims to develop a predictive model for the mutation in patients with LUAD by integrating clinical, dual-energy spectral computed tomography (DESCT), and radiomics features.

View Article and Find Full Text PDF

Objectives: This study evaluates the performance of a clinical dual-source photon-counting computed tomography (PCCT) system in quantifying iodine within calcified vessels, using 3D- printed phantoms with vascular-like structures lined with calcium.

Methods: Parameters assessed include lumen diameters (4, 6, 8, 10, and 12 mm), phantom sizes (S: 20×20 cm, M: 25×25 cm, L: 30×40 cm, XL: 40×50 cm, representing the 99th percentile of US patient sizes), and iodine concentrations (2, 5, and 10 mg/mL). Scans were performed at radiation dose levels of 5, 10, 15, and 20 mGy to systematically evaluate iodine quantification accuracy and spectral imaging performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!