Background: A fixed screw-retained full-arch restoration supported by four implants is a popular treatment option for edentulous arches. Optimal alignment of implants is quite challenging in extremely atrophied edentulous cases, and a small amount of deviation is expected during guided surgery. This study aimed to compare implant accuracy among edentulous jaws with various levels of atrophy.

Methods: Five separate copies of each Cawood and Howell model (III-V) were produced for the maxilla and mandible. A total of 120 implants (30 models). The implant accuracy was assessed based on angular deviations at the base (angle, 3D offset, distal, vestibular, and apical) and tip (3D offset, distal, vestibular, and apical).

Results: The atrophy level of the jaws had a statistically significant effect on deviation; implants showed greater deviation from the planned location as the atrophy level increased.

Conclusion: Given that implant deviation increased with the degree of atrophy, a greater safety margin from important anatomical structures is recommended when planning implant location for guided surgery in Cawood and Howell V cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10466718PMC
http://dx.doi.org/10.1186/s13005-023-00387-wDOI Listing

Publication Analysis

Top Keywords

guided surgery
12
supported implants
8
implant accuracy
8
cawood howell
8
offset distal
8
distal vestibular
8
atrophy level
8
implant
5
implants
5
level alveolar
4

Similar Publications

Decision support guided fluid challenges and stroke volume response during high-risk surgery: a post hoc analysis of a randomized controlled trial.

J Clin Monit Comput

January 2025

Department of Anaesthesiology and Intensive Care, Bicetre hospital, Assistance Publique Hôpitaux de Paris (AP-HP), Le Kremlin Bicetre, France.

Intravenous fluid is administered during high-risk surgery to optimize stroke volume (SV). To assess ongoing need for fluids, the hemodynamic response to a fluid bolus is evaluated using a fluid challenge technique. The Acumen Assisted Fluid Management (AFM) system is a decision support tool designed to ease the application of fluid challenges and thus improve fluid administration during high-risk surgery.

View Article and Find Full Text PDF

The surgical risk is higher for obese patients undergoing laparoscopic left hemicolectomy. To enhance the surgical safety and efficacy for obese patients, we have innovatively integrated the advantages of various surgical approaches to modify a pancreas-guided C-shaped surgical procedure. The safety and quality were assessed through a retrospective analysis.

View Article and Find Full Text PDF

Ultrasmall Au-GRHa Nanosystem for FL/CT Dual-Mode Imaging-Guided Targeting Photothermal Therapy of Ovarian Cancer.

Anal Chem

January 2025

State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, China.

As the most common and lethal cancer of the female gonads, ovarian cancer (OC) has a grave impact on people's health. OC is asymptomatic, insidious in onset, difficult to diagnose and treat, fast-growing, and easy to metastasize and has poor prognosis and high mortality. How to detect OC as early as possible and treat it without side effects has become a challenging medical problem.

View Article and Find Full Text PDF

Classification systems for Adolescent Idiopathic Scoliosis (AIS) play an important role in guiding both surgical planning and conservative treatments. Traditional 2D classification systems, such as the Lenke, King and Lehnert-Schroth classifications, have been widely used for the clinical diagnosis and treatment of scoliosis. However, with the growing understanding of the three-dimensional nature of scoliosis and advancements in 3D reconstruction technologies, 3D classification systems are gaining increasing attention.

View Article and Find Full Text PDF

Lumbar Erector Spinae Plane Block Provides Effective Postoperative Analgesia in Hip Fracture Surgery.

J Coll Physicians Surg Pak

January 2025

Department of Orthopaedics and Traumatology, Faculty of Medicine, Sakarya University, Sakarya, Turkiye.

Objective: To compare the postoperative analgesic effectiveness of ultrasound-guided lumbar erector spinae plane (LESP) block with lumbar plexus block (LPB) in patients operated for proximal femur fractures.

Study Design: A randomised controlled trial. Place and Duration of the Study: Sakarya Training and Research Hospital Operation Theatre, Sakarya, Turkiye, between January and June 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!