AI Article Synopsis

  • - This study compares the effectiveness of 1.5 T versus 3 T magnetic resonance angiography (MRA) in detecting cerebral aneurysms using a specialized deep learning detection software called EIRL aneurysm®.
  • - Researchers analyzed MRA scans from 90 patients and found that while both 1.5 T and 3 T MRA had high sensitivity for detecting aneurysms, the 3 T MRA resulted in significantly more false positives.
  • - The most common reasons for false positives were related to vessel origins, flow-related artifacts, and atherosclerosis; the findings aim to assist less experienced physicians in accurately diagnosing aneurysms with the EIRL_an software.

Article Abstract

Purpose: To compare the diagnostic performance of 1.5 T versus 3 T magnetic resonance angiography (MRA) for detecting cerebral aneurysms with clinically available deep learning-based computer-assisted detection software (EIRL aneurysm® [EIRL_an]), which has been approved by the Japanese Pharmaceuticals and Medical Devices Agency. We also sought to analyze the causes of potential false positives.

Methods: In this single-center, retrospective study, we evaluated the MRA scans of 90 patients who underwent head MRA (1.5 T and 3 T in 45 patients each) in clinical practice. Overall, 51 patients had 70 aneurysms. We used MRI from a vendor not included in the dataset used to create the EIRL_an algorithm. Two radiologists determined the ground truth, the accuracy of the candidates noted by EIRL_an, and the causes of false positives. The sensitivity, number of false positives per case (FPs/case), and the causes of false positives were compared between 1.5 T and 3 T MRA. Pearson's χ test, Fisher's exact test, and the Mann‒Whitney U test were used for the statistical analyses as appropriate.

Results: The sensitivity was high for 1.5 T and 3 T MRA (0.875‒1), but the number of FPs/case was significantly higher with 3 T MRA (1.511 vs. 2.578, p < 0.001). The most common causes of false positives (descending order) were the origin/bifurcation of vessels/branches, flow-related artifacts, and atherosclerosis and were similar between 1.5 T and 3 T MRA.

Conclusion: EIRL_an detected significantly more false-positive lesions with 3 T than with 1.5 T MRA in this external validation study. Our data may help physicians with limited experience with MRA to correctly diagnose aneurysms using EIRL_an.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00234-023-03216-8DOI Listing

Publication Analysis

Top Keywords

15 t 3 t
16
false positives
12
3 t mra
12
3 t magnetic
8
magnetic resonance
8
resonance angiography
8
detecting cerebral
8
cerebral aneurysms
8
deep learning-based
8
learning-based computer-assisted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!