Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The Platelet Function Analyzer 200 (PFA-200; Siemens) is an in vitro substitute for in vivo bleeding time that is designed to investigate platelet function in a more physiologic manner than traditional aggregometry. The analyzer reports a closure time (CT) as a marker of platelet function, and may also report the calculated platelet function measurement primary hemostasis components, PHC1 and PHC2. These incorporate the measured total volume (TV) of blood aspirated and the initial flow rate (IF). We determined, for the COL/ADP and P2Y cartridges, the median total volume (TV), and RIs for CT, IF, TV, PHC1, and PHC2, and investigated the sensitivity and specificity of those parameters at the determined interpretation thresholds in determination of the clopidogrel effect. Healthy client-owned cats were recruited prospectively to determine RIs for CT, IF, TV, PHC1, and PHC2. Healthy blood-donor cats and cats on clopidogrel therapy were included retrospectively to determine test performance. In 20 healthy cats, RIs for COL/ADP were CT (19.5-87.2 s), IF (199-278 µL/min), TV (199-332 µL), PHC1 (94-106%), and PHC2 (52-148%); and for P2Y, CT (4.2-94.3 s), IF (112-208 µL/min), TV (151-294 µL), PHC1 (35-178%), and PHC2 (90-109%). CVs were calculated for all of these values. Specificity for detection of the clopidogrel effect was calculated from a group of healthy blood donors, and sensitivity for detection of the clopidogrel effect from a group of cats with known clopidogrel effect. Sensitivity and specificity were, for COL/ADP: CT (83.3%, 66.6%), IF (41.4%, 83.3%), TV (83.3%, 100%), PHC1 (100%, 100%) and PHC2 (100%, 83.3%); and for P2Y: CT (100%, 94.4%), IF (30%, 44.4%), TV (100%, 94.4%), PHC1 (100%, 100%), and PHC2 (100%, 97.7%). These PFA-200 values may be beneficial in the determination of platelet function in cats.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621536 | PMC |
http://dx.doi.org/10.1177/10406387231197440 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!