Despite the accuracy of confirmatory tests for the diagnosis of human T cell lymphotropic virus (HTLV), inconclusive or false-negative results still occur when diagnosing human T cell lymphotropic virus type 2 (HTLV-2)-positive patients. The goal of this study was to evaluate the sensitivity and accuracy of a confirmatory immunoassay, the Multi-HTLV assay. A total of 246 plasma samples were tested by real-time polymerase chain reaction (qPCR) and used to calculate the sensitivity and typing accuracy of the Multi-HTLV assay. Of the 246 plasma samples, 127 were positive for human T cell lymphotropic virus type 1 (HTLV-1), 112 were positive for HTLV-2, and 7 were positive for both HTLV-1 and HTLV-2. Thereafter, the nonparametric Mann-Whitney U test was used to calculate the concordance between the qPCR test and Multi-HTLV assay in 12 samples with discrepant and inconclusive qPCR results. The Multi-HTLV assay showed high performance in identifying HTLV-1 and HTLV-2 with sensitivities of 97% [95% confidence interval (CI): 0.92-0.98] and 94% (0.87-0.96), respectively. However, due to typing performance (98% for HTLV-1 and 94% for HTLV-2), it had 95% agreement with positive HTLV-1 qPCR results (95% CI: 90.07-97.81) and 86% (78.04-91.01) of HTLV-2 qPCR results were positive. Moreover, this test was able to recognize 80% of indeterminate samples and all HTLV-2 positive samples that showed false-negative qPCR results. Our findings, derived from a substantial number of HTLV-positive samples, underscore the inherent reliability and feasibility of the Multi-HTLV assay, regardless of the molecular testing facilities. Furthermore, the distinctive multiparametric nature of this assay, combined with its straightforward procedural execution, introduces novel perspectives for analyzing specific serological profiles in each patient, as well as the potential for immunological monitoring of disease progression.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/AID.2022.0174 | DOI Listing |
AIDS Res Hum Retroviruses
March 2024
Laboratory of Medical Investigation LIM-56, Division of Clinical Dermatology and Immunodeficiencies, University of São Paulo School of Medicine, São Paulo, Brazil.
Despite the accuracy of confirmatory tests for the diagnosis of human T cell lymphotropic virus (HTLV), inconclusive or false-negative results still occur when diagnosing human T cell lymphotropic virus type 2 (HTLV-2)-positive patients. The goal of this study was to evaluate the sensitivity and accuracy of a confirmatory immunoassay, the Multi-HTLV assay. A total of 246 plasma samples were tested by real-time polymerase chain reaction (qPCR) and used to calculate the sensitivity and typing accuracy of the Multi-HTLV assay.
View Article and Find Full Text PDFPLoS Negl Trop Dis
November 2021
InfYnity Biomarkers, Lyon, France.
Background: Human T-Cell Lymphotropic Viruses (HTLV) type 1 and type 2 account for an estimated 5 to 10 million infections worldwide and are transmitted through breast feeding, sexual contacts and contaminated cellular blood components. HTLV-associated syndromes are considered as neglected diseases for which there are no vaccines or therapies available, making it particularly important to ensure the best possible diagnosis to enable proper counselling of infected persons and avoid secondary transmission. Although high quality antibody screening assays are available, currently available confirmatory tests are costly and have variable performance, with high rates of indeterminate and non-typable results reported in many regions of the world.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!