This study aims at evaluating the effect of simulating porcelain firing on the microstructure, corrosion behavior and mechanical properties of a Co-Cr-Mo alloy fabricated by Metal Soft Milling (MSM). Two groups of Co-28Cr-5Mo specimens (25 × 20 × 3 mm) were prepared by MSM: The as-sintered (AS) specimens and the post-fired (PF) specimens that were subjected to 5 simulating porcelain firing cycles without applying the ceramic mass onto their surface. Phase identification by X-ray Diffraction (XRD), microstructure examination by optical microscopy and Scanning Electron Microscopy combined with Energy-Dispersive X-ray Spectroscopy (SEM/EDX), corrosion testing by cyclic polarization and chronoamperometry in simulated body fluid (SBF), the latter test accompanied by Cr and Cr detection in the electrolyte through the 1.5-diphenylcarbazide (DPC) method and UV/visible spectrophotometry, and mechanical testing by micro-/nano-indentation were conducted to evaluate the effect of the post-firing cycles on the properties of Co-Cr-Mo. The results were statistically analyzed by the t test (p < 0.05: statistically significant). All specimens had a mixed γ-fcc and ε-hcp cobalt-based microstructure with a dispersion of pores filled with SiO and a fine MC intergranular presence. PF led to an increase in the ε-Co content and slight grain coarsening. Both AS and PF alloys showed high resistance to general and localized corrosion, whereas neither Cr nor Cr were detected during the passivity-breakdown stage. PF improved the mechanical properties of the AS-alloy, especially the indentation modulus and true hardness (statistically significant differences: p = 0.0009 and 0.006, respectively). MSM and MSM/simulating-porcelain firing have been proven trustworthy fabrication methods of Co-Cr-Mo substrates for metal-ceramic prostheses. Moreover, the post-firing cycles improve the mechanical behavior of Co-Cr-Mo, which is vital under the dynamically changing loads in the oral cavity, whereas they do not degrade the corrosion performance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10925571 | PMC |
http://dx.doi.org/10.1007/s10266-023-00849-2 | DOI Listing |
BMC Oral Health
January 2025
Department of Prosthodontics, Faculty of Dentistry, Recep Tayyip Erdoğan University, Rize, Turkey.
Background: Zygomatic implants are becoming an ideal treatment approach for implant-supported prosthesis treatment developed for the atrophic maxilla. This study aims to evaluate the amount and distribution of stress in implants and peri-implant bone using different implant-supported prosthesis configurations in Aramany Class I maxillary defects through 3-dimensional finite element analysis.
Methods: A 3-dimensional finite element model of the Aramany class I defect was created.
J Prosthodont
January 2025
Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Lagoa Nova, Natal, Brazil.
Purpose: To assess the impact of staining and multiple firings on the mechanical, optical, and surface characteristics of zirconia-containing lithium silicate ceramics (ZLS).
Materials And Methods: Ninety ZLS discs (Suprinity, VITA Zahnfabrick) were divided according to the "Number of firings" protocol: Ctr-control, no characterization; SC-single firing cycle (for characterization, crystallization and staining simultaneously); and DC-double firing cycle (crystallization firing cycle was performed separately from the staining firing). Extrinsic pigmentation was performed to replicate the characterization of a monolithic restoration.
BMC Oral Health
January 2025
Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt.
Purpose: The current study aimed to compare modified Polyether-ether-ketone's fracture resistance and failure mode versus lithium disilicate glass-ceramic endocrowns.
Materials And Methods: A total of 16 butt-joint endocrown specimens on mandibular second molar teeth were fabricated and divided into two equivalent groups; Pressable modified Polyether-ether-ketone (PEEK) (BioHPP) and Pressable lithium disilicate glass ceramic (IPS e.max Press).
J Prosthodont
December 2024
Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran.
Purpose: Metal-ceramic screw-retained implant restorations persist as a fundamental choice in specific clinical scenarios. Little is known about the effects of fabrication steps and aging on their structural properties. This study aimed to investigate how laboratory fabrication procedures and thermomechanical loading affect the structural properties of screw-retained metal-ceramic implant restorations.
View Article and Find Full Text PDFDent Mater
February 2025
Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt; Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK. Electronic address:
Objectives: The growing trend of minimally invasive approaches has encouraged the application of partial coverage designs in restorative dentistry. This study aimed to evaluate the cyclic fatigue performance of different CAD-CAM materials used in various partial coverage designs for premolar restorations.
Methods: A freshly extracted upper premolar was prepared using a high-speed handpiece to create mesio-occluso-distal (MOD) cavities with standardized dimensions.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!