A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Problems Affecting Accurate Dose Measurement in Small-Field for Linear Accelerator. | LitMetric

Background: The use of relatively narrow fields has become necessary with the advent of intricate and accurate radiation therapy delivery dose to patients; therefore, small-field dosimetry faces several difficulties. Both dose calculations and measurements require to be performed with extra care, due to the uncertainty that might be increased by using such small field sizes.

Material And Methods: In this study, we investigated the effect of detectors size on the dosimetry of small fields [starting with radiation fields from (1cm x 1cm), (2cm x 1cm), and (3cm x 1cm)...etc., up to (4cm x 5cm) and (5cm x 5cm)]. We used the linear accelerator and different types of ionization chambers i.e. [Farmer FC65-P, CC13, and CC01 (pinpoint)] an addition to semiconductors i.e. (IBA Razor diode)], and we investigated all detectors to read the absorbed dose in water under the reference conditions (field 10cm x10cm, SSD 100cm and depth 10cm).

Results: While measuring the absolute dose under reference conditions, all detectors had a non-significant difference of less than ±2%, except for the Razor diode, which showed a significant difference of ± 5%. On the other hand, when small fields were measured, we discovered a significant difference of 48%, compared to the Razor diode.

Conclusion: The Razor diode is more stable in small-field dosimetry than other detectors. Also, the Razor Diode is intended for relative dosimetry but, it shall not be used for absolute dose measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10685229PMC
http://dx.doi.org/10.31557/APJCP.2023.24.8.2757DOI Listing

Publication Analysis

Top Keywords

razor diode
12
linear accelerator
8
small-field dosimetry
8
investigated detectors
8
small fields
8
reference conditions
8
absolute dose
8
dose
6
razor
5
problems accurate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!