Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The objectives of this study were to evaluate different analytical methods to determine colostrum quality in dairy cattle, including one laboratory-based method (ELISA) and 4 on-farm tests. We hypothesized that the colostral IgG concentration using different analytical methods, such as ELISA (mg/mL), digital Brix refractometer (% Brix), colostrometer (specific gravity and mg/mL), an outflow funnel (seconds), and a lateral flow assay (mg/mL), were highly correlated with the reference method, radial immunodiffusion (RID; mg/mL) and would generate comparable results. Colostrum samples were collected from 209 Holstein Friesian cows on 2 commercial dairy farms in Germany. Colostrum weight and colostrum temperature were measured. Test characteristics, such as optimum thresholds, sensitivity, specificity, and area under the curve (AUC) were determined using a receiver operating characteristic curve analyses for each test. Out of 209 colostrum samples assessed by RID, 186 (89%) samples had high quality (≥50 mg IgG/mL), while 23 colostrum samples (11%) showed poor quality with IgG concentrations less than 50 mg/mL. The mean IgG concentration (±SD) was 101.3 ± 45.9 mg/mL and the range was 6.0 to 244.3 mg/mL. The Pearson correlation coefficient (r) between RID and ELISA was r = 0.78. In comparison to RID, Pearson correlation coefficients for the on-farm tests were: r = 0.79 (digital Brix refractometry), r = 0.58 (colostrometer: specific gravity), r = 0.61 (colostrometer: temperature corrected), r = 0.26 (outflow funnel) and r = 0.43 (lateral flow assay), respectively. The optimal threshold to identify high-quality colostrum using ELISA was 50.8 mg/mL with sensitivity 91.3%, specificity 92.3%, and AUC of 0.94. For the on-farm tests sensitivity ranged from 95.7% (Brix refractometry) to 60.9% (lateral flow assay). Specificity ranged from 88.6% (lateral flow assay) to 75.9% (colostrometer: temperature corrected). The AUC ranged from 0.93 (Brix refractometry) to 0.73 (outflow funnel). Based on the AUC, ELISA (0.94) and Brix refractometry (0.93) can be considered highly accurate. In conclusion, the ELISA is accurate to assess colostrum quality. Regarding the on-farm tests only the digital Brix refractometer and the colostrometer were adequate to determine colostrum quality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3168/jds.2023-23467 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!