A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Effectiveness of Continuous Glucose Monitoring Devices in Managing Uncontrolled Diabetes Mellitus: A Retrospective Study. | LitMetric

This retrospective study aimed to assess the effectiveness of continuous glucose monitoring (CGM) devices in managing uncontrolled diabetes mellitus (DM). The study cohort comprised 25 patients with uncontrolled diabetes who received treatment at an internal medicine resident clinic. The objective was to evaluate the impact of transitioning from self-monitoring of blood glucose (SMBG) to CGM devices on glycemic control, as measured by changes in hemoglobin A1c (HbA1c) levels, average blood glucose levels, hypoglycemic events, time spent within the target blood sugar range, and glucose variability. The findings indicated significant improvements in glycemic control with the adoption of CGM devices, highlighting their potential benefits for optimizing diabetes management. The study is particularly interesting because it was done in an internal medicine continuity clinic with the main participation of the internal medicine residents under the supervision of an endocrinologist. It was not done as the majority of the other studies used CGM in specialized endocrinology clinics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10460137PMC
http://dx.doi.org/10.7759/cureus.42545DOI Listing

Publication Analysis

Top Keywords

uncontrolled diabetes
12
cgm devices
12
internal medicine
12
effectiveness continuous
8
continuous glucose
8
glucose monitoring
8
devices managing
8
managing uncontrolled
8
diabetes mellitus
8
retrospective study
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!