Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Technical advances in microsurgery have enabled complex oncological reconstructions by performing free tissue transfers, nerve and lymphatic reconstructions. However, the manual abilities required to perform microsurgery can be affected by human fatigue and physiological tremor resulting in tissue damage and compromised outcomes. Robotic assistance has the potential to overcome issues of manual microsurgery by improving clinical value and anastomoses' outcomes. The Symani Surgical System, a robotic platform designed for microsurgery, was used in this in-vivo preclinical study using a rat animal model. The tests included anastomoses on veins and arteries performed by microsurgeons manually and robotically, with the latter approach using Symani. The anastomoses were assessed for patency, histopathology, and execution time. Patency results confirmed that the robotic and manual techniques for venous and arterial anastomoses were equivalent after anastomosis, however, the time to perform the anastomosis was longer with the use of the robot (p < 0.0001). Histological analysis showed less total average host reaction score at the anastomotic site in robotic anastomosis for both veins and arteries. This study demonstrates the equivalence of vessel patency after microsurgical anastomoses with the robotic system and with manual technique. Furthermore, robotic anastomosis has proven to be slightly superior to manual anastomosis in terms of decreased tissue damage, as shown by histological analysis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10460789 | PMC |
http://dx.doi.org/10.1038/s41598-023-41143-z | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!