Making clinical sense of 3-dimensional metrology software programs.

J Prosthet Dent

Professor Emeritus, Department of Prosthodontics, New York University College of Dentistry, New York, NY. Electronic address:

Published: May 2024

Three-dimensional (3D) metrology software programs were designed to allow the user to capture and process the data from 3D scanners and other devices to measure, understand, and communicate inspection results to ensure manufacturing quality. Its use in dentistry has increased with concerns over how to make clinically significant decisions based on the data provided. The data produced by a commonly used software program was reviewed, and a rationale for interpreting that data was presented. The requirements for trueness, precision, and tolerance were also reviewed. In addition, contact was made with Oqton Tech Support, who is responsible for the Geomagic software program. The arithmetic average and the root mean square (RMS) do not identify the amount of deviation nor the direction and may not be helpful in determining how to use the data. RMS, and other statistical approaches, can show that there was a deviation but do not tell how much and in what direction. For prosthodontic studies, the 3D color map is the most efficacious method of determining the clinical significance of 3D metrology software.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2023.06.021DOI Listing

Publication Analysis

Top Keywords

metrology software
12
software programs
8
software program
8
software
5
data
5
making clinical
4
clinical sense
4
sense 3-dimensional
4
3-dimensional metrology
4
programs three-dimensional
4

Similar Publications

A data management system for precision medicine.

PLOS Digit Health

January 2025

Clinical Care & Research, ORTEC B.V., Zoetermeer, The Netherlands.

Precision, or personalised medicine has advanced requirements for medical data management systems (MedDMSs). MedDMS for precision medicine should be able to process hundreds of parameters from multiple sites, be adaptable while remaining in sync at multiple locations, real-time syncing to analytics and be compliant with international privacy legislation. This paper describes the LogiqSuite software solution, aimed to support a precision medicine solution at the patient care (LogiqCare), research (LogiqScience) and data science (LogiqAnalytics) level.

View Article and Find Full Text PDF

The current study assesses several water-based PVT system thermal absorber configurations. The thermal absorber in PVT system plays a vital role in efficiency evaluation as it lowers PV temperature and collects heat energy. The current study aims to discover and analyze advanced thermal absorber design by comparing well-received spiral circular absorbers and non-cooled PV with proposed semi-circular thermal absorbers with varying flow configurations.

View Article and Find Full Text PDF

Dentistry is steadily evolving along the digital pathway at a constant and sure pace. Intraoral scanners (IOSs) started to enhance the precision and trueness of the restorations, making prosthodontics treatment more predictable. The objective of this study was to compare the trueness and internal fit of the printed provisional veneers for 60 preparations with three different types of finish lines.

View Article and Find Full Text PDF

Investigation of factors affecting the sound absorption behaviour of 3D printed hexagonal prism lattice polyamide structures.

Sci Rep

December 2024

Faculty of Mechanical Engineering, Department of Machining, Assembly and Engineering Metrology, VSB-Technical University of Ostrava, Ostrava-Poruba, 708 00, Czech Republic.

The aim of this work is to investigate the sound absorption properties of open-porous polyamide 12 (PA12) structures produced using Selective Laser Sintering (SLS) technology. The examined 3D-printed samples, fabricated with hexagonal prism lattice structures, featured varying thicknesses, cell sizes, and orientations. Additionally, some samples were produced with an outer shell to evaluate its impact on sound absorption.

View Article and Find Full Text PDF

Background: For the development and validation of dynamic treatment modalities and processes on the MR-linac, independent measurements should be performed that validate dose delivery and linac behavior at a high temporal resolution. To achieve this, a detector with both high temporal and spatial resolution is necessary.

Purpose: This study investigates the suitability of a Delta4 Phantom+ MR (Delta4) detector array for time-resolved dosimetry in the 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!