Download full-text PDF |
Source |
---|
Magn Reson Med
January 2025
Department of Radiology, University of Missouri, Columbia, Missouri, USA.
Purpose: The aim of the work is to develop a cascaded diffusion-based super-resolution model for low-resolution (LR) MR tagging acquisitions, which is integrated with parallel imaging to achieve highly accelerated MR tagging while enhancing the tag grid quality of low-resolution images.
Methods: We introduced TagGen, a diffusion-based conditional generative model that uses low-resolution MR tagging images as guidance to generate corresponding high-resolution tagging images. The model was developed on 50 patients with long-axis-view, high-resolution tagging acquisitions.
Magn Reson Med
January 2025
Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
Purpose: This work aims to raise a novel design for navigator-free multiband (MB) multishot uniform-density spiral (UDS) acquisition and reconstruction, and to demonstrate its utility for high-efficiency, high-resolution diffusion imaging.
Theory And Methods: Our design focuses on the acquisition and reconstruction of navigator-free MB multishot UDS diffusion imaging. For acquisition, radiofrequency-pulse encoding was used to achieve controlled aliasing in parallel imaging in MB imaging.
Patient Saf Surg
January 2025
NTNU - Norwegian University of Science and Technology, Trondheim, Norway.
Background: Meniscal surgery is one of the most frequent orthopaedic procedures performed worldwide. There is a wide range of possible treatment errors that can occur following meniscal surgery. In Norway, patients subject to treatment errors by hospitals and private institutions can file a compensation claim free of charge to the Norwegian System of Patient Injury Compensation (NPE).
View Article and Find Full Text PDFBMC Med Inform Decis Mak
January 2025
Global and Tropical Health Division, Menzies School of Health Research, Charles Darwin University, Dili, Timor-Leste.
Background: Effective diagnostic capacity is crucial for clinical decision-making, with up to 70% of decisions in high-resource settings based on laboratory test results. However, in low- and middle-income countries (LMIC) access to diagnostic services is often limited due to the absence of Laboratory Information Management Systems (LIMS). LIMS streamline laboratory operations by automating sample handling, analysis, and reporting, leading to improved quality and faster results.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
College of Optometry, University of Houston College of Optometry, 4401 Martin Luther King Blvd, 77204-2020, Houston, TX, USA.
Background: This study evaluates retinal oxygen saturation and vessel density within the macula and correlates these measures in controls and subjects with type 2 diabetes (DM) with (DMR) and without (DMnR) retinopathy. Changes in retinal oxygen saturation have not been evaluated regionally in diabetic patients.
Methods: Data from seventy subjects (28 controls, 26 DMnR, and 16 DMR were analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!