To Bag or Not to Bag? How AudioMoth-Based Passive Acoustic Monitoring Is Impacted by Protective Coverings.

Sensors (Basel)

Institute of Sound and Vibration Research, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK.

Published: August 2023

Bare board AudioMoth recorders offer a low-cost, open-source solution to passive acoustic monitoring (PAM) but need protecting in an enclosure. We were concerned that the choice of enclosure may alter the spectral characteristics of recordings. We focus on polythene bags as the simplest enclosure and assess how their use affects acoustic metrics. Using an anechoic chamber, a series of pure sinusoidal tones from 100 Hz to 20 kHz were recorded on 10 AudioMoth devices and a calibrated Class 1 sound level meter. The recordings were made on bare board AudioMoth devices, as well as after covering them with different bags. Linear phase finite impulse response filters were designed to replicate the frequency response functions between the incident pressure wave and the recorded signals. We applied these filters to ~1000 sound recordings to assess the effects of the AudioMoth and the bags on 19 acoustic metrics. While bare board AudioMoth showed very consistent spectral responses with accentuation in the higher frequencies, bag enclosures led to significant and erratic attenuation inconsistent between frequencies. Few acoustic metrics were insensitive to this uncertainty, rendering index comparisons unreliable. Biases due to enclosures on PAM devices may need to be considered when choosing appropriate acoustic indices for ecological studies. Archived recordings without adequate metadata may potentially produce biased acoustic index values and should be treated cautiously.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10457934PMC
http://dx.doi.org/10.3390/s23167287DOI Listing

Publication Analysis

Top Keywords

bare board
12
board audiomoth
12
acoustic metrics
12
passive acoustic
8
acoustic monitoring
8
audiomoth devices
8
acoustic
7
audiomoth
5
bag bag?
4
bag? audiomoth-based
4

Similar Publications

Aim This study aims to evaluate the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) check and revision procedures performed in a freestanding interventional radiology (IR) outpatient facility. Methodology A total of 40 patients (male 31:female 9, median age 60 years old) underwent a TIPS check and/or revision at a freestanding IR outpatient facility between 2009 and 2017. Procedures were performed using a mobile C-arm unit under intravenous (IV) moderate sedation, with the patient discharged home on the same day.

View Article and Find Full Text PDF

Despite the ubiquitous use of glasses, their simultaneous susceptibility toward scratch-induced defects and atmospheric hydration deteriorates their mechanical and chemical durability. Here, it is demonstrated that the deposition of a few-layer graphene provides unprecedented wear resistance to silica glass in aqueous conditions. To this extent, nanoscale scratch tests are carried out on graphene-glass surfaces via contact-mode atomic force microscopy with chemically inert and reactive tips.

View Article and Find Full Text PDF

Effect of wearable robot Bot Fit's hip joint-centered assist torque and voice coach on walking.

BMC Musculoskelet Disord

December 2024

Department of Physical Therapy, Applied Physical Therapy Lab, College of Future Convergence, Sahmyook University, Seoul, 01795, Republic of Korea.

Background: The main key to the 4th industrial era is robots, and wearable robots are incorporated into human healthcare. Samsung Electronics' Bot Fit is a hip joint-centered assistive robot that can induce walking posture and energetic walking exercises.

Methods: This study is a cross-section study.

View Article and Find Full Text PDF

Background: The relationship between the extent and severity of stress-induced ischemia and the extent and severity of anatomic coronary artery disease (CAD) in patients with obstructive CAD is multifactorial and includes the intensity of stress achieved, type of testing used, presence and extent of prior infarction, collateral blood flow, plaque characteristics, microvascular disease, coronary vasomotor tone, and genetic factors. Among chronic coronary disease participants with site-determined moderate or severe ischemia, we investigated associations between ischemia severity on stress testing and the extent of CAD on coronary computed tomography angiography.

Methods: Clinically indicated stress testing included nuclear imaging, echocardiography, cardiac magnetic resonance imaging, or nonimaging exercise tolerance test.

View Article and Find Full Text PDF
Article Synopsis
  • Hemoptysis, the coughing up of blood, can stem from various serious underlying conditions, but often involves high-pressure bronchial arteries; Bronchial artery embolization (BAE) is typically the first-line treatment despite varying long-term success rates.
  • A 12-year-old boy with a history of massive hemoptysis underwent multiple BAEs and recent imaging confirmed the location of previous coils; however, he experienced another episode where traditional intervention was complicated by prior treatments.
  • The medical team opted for a thoracoscopic approach, successfully isolating and ligating the problematic vessel, leading to the patient's stabilization and discharge after four days.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!