Marginal spectrum (MS) feature information of humpback whale vocalization (HWV) signals is an interesting and significant research topic. Empirical mode decomposition (EMD) is a powerful time-frequency analysis tool for marine mammal vocalizations. In this paper, new MS feature innovation information of HWV signals was extracted using the EMD analysis method. Thirty-six HWV samples with a time duration of 17.2 ms were classified into Classes I, II, and III, which consisted of 15, 5, and 16 samples, respectively. The following ratios were evaluated: the average energy ratios of the 1 first intrinsic mode function (IMF1) and residual function (RF) to the referred total energy for the Class I samples; the average energy ratios of the IMF1, 2nd IMF (IMF2), and RF to the referred total energy for the Class II samples; the average energy ratios of the IMF1, 6th IMF (IMF6), and RF to the referred total energy for the Class III samples. These average energy ratios were all more than 10%. The average energy ratios of IMF1 to the referred total energy were 9.825%, 13.790%, 4.938%, 3.977%, and 3.32% in the 2980-3725, 3725-4470, 4470-5215, 10,430-11,175, and 11,175-11,920 Hz bands, respectively, in the Class I samples; 14.675% and 4.910% in the 745-1490 and 1490-2235 Hz bands, respectively, in the Class II samples; 12.0640%, 6.8850%, and 4.1040% in the 2980-3725, 3725-4470, and 11,175-11,920 Hz bands, respectively, in the Class III samples. The results of this study provide a better understanding, high resolution, and new innovative views on the information obtained from the MS features of the HWV signals.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10458355PMC
http://dx.doi.org/10.3390/s23167228DOI Listing

Publication Analysis

Top Keywords

average energy
20
energy ratios
20
referred total
16
total energy
16
class samples
16
hwv signals
12
energy class
12
samples average
12
ratios imf1
12
bands class
12

Similar Publications

Objective: Spinopelvic sagittal balance ensures efficient posture and minimizes energy expenditure by aligning the spine, pelvis, and lower extremities. Deviations can cause clinical issues like back pain and functional limitations. Key radiographic parameters, including pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), and lumbar lordosis (LL), are essential for evaluating spinal pathologies and planning surgeries.

View Article and Find Full Text PDF

Titanium dioxide nanotube arrays (TNTs) generated in situ on the surface of dental implants have been shown to enhance bone integration for load-bearing support while managing load distribution and energy dissipation to prevent bone resorption from overload. However, their inadequate stability limits the clinical use of conventional TNTs. This study introduces an innovative approach to improve the mechanical stability of TNTs while maintaining their bone-integration efficiency.

View Article and Find Full Text PDF

A green facile method was developed to synthesize the carbon quantum dots from barberry, a native plant, as a new carbon source. The synthesis strategy is a simple one-step hydrothermal process without requiring hazardous chemical reagents. The spherical structure of b-CDs with an average particle size of 3.

View Article and Find Full Text PDF

Critical source areas (CSAs) can act as a source of phosphorus (P) in surface waters by releasing soil P to porewater during frequent rainfall events. The extent of P release under short-term, frequent submergence has not been systematically studied in CSAs in New Zealand. A study was conducted to explore the potential of three contrasting dairy and sheep/beef farm soils (Recent, Pallic and Allophanic soils) to release P to porewater and pondwater under short-term and frequent submergence.

View Article and Find Full Text PDF

The effect of bone relaxation on the simulated pull-off force of a cementless femoral knee implant.

J Biomech

January 2025

Radboudumc, Orthopaedic Research Lab, PO Box 9101, 6500 HB Nijmegen, the Netherlands.

Aseptic loosening is the primary cause of revision in cementless total knee arthroplasty (TKA), emphasizing the importance of strong initial stability for long-term implant success. Pre-clinical evaluations are crucial for understanding implant fixation mechanics and improving implant designs. Finite element (FE) analysis models often use linear elastic bone material models, which do not accurately reflect bone's mechanical behavior.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!