Gait Stride Length Estimation Using Embedded Machine Learning.

Sensors (Basel)

REVAL Rehabilitation Research Center, Faculty of Rehabilitation Sciences, Hasselt University, 3590 Diepenbeek, Belgium.

Published: August 2023

Introduction: Spatiotemporal gait parameters, e.g., gait stride length, are measurements that are classically derived from instrumented gait analysis. Today, different solutions are available for gait assessment outside the laboratory, specifically for spatiotemporal gait parameters. Such solutions are wearable devices that comprise an inertial measurement unit (IMU) sensor and a microcontroller (MCU). However, these existing wearable devices are resource-constrained. They contain a processing unit with limited processing and memory capabilities which limit the use of machine learning to estimate spatiotemporal gait parameters directly on the device. The solution for this limitation is embedded machine learning or tiny machine learning (tinyML). This study aims to create a machine-learning model for gait stride length estimation deployable on a microcontroller.

Materials And Method: Starting from a dataset consisting of 4467 gait strides from 15 healthy people, measured by IMU sensor, and using state-of-the-art machine learning frameworks and machine learning operations (MLOps) tools, a multilayer 1D convolutional float32 and int8 model for gait stride length estimation was developed.

Results: The developed float32 model demonstrated a mean accuracy and precision of 0.23 ± 4.3 cm, and the int8 model demonstrated a mean accuracy and precision of 0.07 ± 4.3 cm. The memory usage for the float32 model was 284.5 kB flash and 31.9 kB RAM. The int8 model memory usage was 91.6 kB flash and 13.6 kB RAM. Both models were able to be deployed on a Cortex-M4F 64 MHz microcontroller with 1 MB flash memory and 256 kB RAM.

Conclusions: This study shows that estimating gait stride length directly on a microcontroller is feasible and demonstrates the potential of embedded machine learning, or tinyML, in designing wearable sensor devices for gait analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10459491PMC
http://dx.doi.org/10.3390/s23167166DOI Listing

Publication Analysis

Top Keywords

machine learning
28
gait stride
20
stride length
20
gait
12
length estimation
12
embedded machine
12
spatiotemporal gait
12
gait parameters
12
int8 model
12
gait analysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!