A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Use of an Inspiration-Synchronized Vibrating Mesh Nebulizer for Prolonged Inhalative Iloprost Administration in Mechanically Ventilated Patients-An In Vitro Model. | LitMetric

Mechanically ventilated patients suffering from acute respiratory distress syndrome (ARDS) frequently receive aerosolized iloprost. Because of prostacyclin's short half-life, prolonged inhalative administration might improve its clinical efficacy. But, this is technically challenging. A solution might be the use of inspiration-synchronized vibrating mesh nebulizers (VMN), which achieve high drug deposition rates while showing prolonged nebulization times. However, there are no data comparing prolonged to bolus iloprost nebulization using a continuous vibrating mesh nebulizer (VMN) and investigating the effects of different ventilation modes on inspiration-synchronized nebulization. Therefore, in an in vitro model of mechanically ventilated adults, a VMN and a VMN were compared in volume-controlled (VC-CMV) and pressure-controlled continuous mandatory ventilation (PC-CMV) regarding iloprost deposition rate and nebulization time. During VC-CMV, the deposition rate of the VMN was comparable to the rate obtained with the VMN, but 10.9% lower during PC-CMV. The aerosol output of the VMN during both ventilation modes was significantly lower compared to the VMN, leading to a 7.5 times longer nebulization time during VC-CMV and only to a 4.2 times longer nebulization time during PC-CMV. Inspiration-synchronized nebulization during VC-CMV mode therefore seems to be the most suitable for prolonged inhalative iloprost administration in mechanically ventilated patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10458390PMC
http://dx.doi.org/10.3390/pharmaceutics15082080DOI Listing

Publication Analysis

Top Keywords

mechanically ventilated
16
vibrating mesh
12
prolonged inhalative
12
nebulization time
12
inspiration-synchronized vibrating
8
mesh nebulizer
8
inhalative iloprost
8
iloprost administration
8
administration mechanically
8
vitro model
8