A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Slight Adjustment in the Weight of Sulfur Sheets to Synthesize β-NiS Nanobelts for Maintaining Detection of Lower Concentrations of Glucose through a Long-Term Storage Test. | LitMetric

The β-nickel sulfide (β-NiS) nanobelts were fabricated by electrodepositing a nickel nanosheet film on Indium tin oxide (ITO)-coated glass substrates and sulfuring the nickel film on ITO-coated glass substrates. The sulfurization method can be used to form nanobelts without a template. A small glass tube was used to anneal the sulfur sheet with a nickel nanosheet film. After applying vacuum to the tube, the specimen was annealed at 500 °C. By adjusting the weight of the sulfur sheet in a small glass tube, a nanobelt structure can be formed on the film for 4 h. The β-NiS nanobelt film had a sulfide and nickel molar ratio that was nearly 0.7 (S/Ni). After five years of a long-term storage test, the β-NiS nanobelt films were able to measure the glucose in a solution with the value of sensitivity of 8.67 µA cm µM. The β-NiS nanobelt film also detected glucose with a limit of low detection (LOD) of around 0.173 µM. The estimation of reproducibility was over 98%. Therefore, the β-NiS nanobelt film has a significant ability to detect low concentrations of glucose in a solution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10460078PMC
http://dx.doi.org/10.3390/nano13162371DOI Listing

Publication Analysis

Top Keywords

β-nis nanobelt
16
nanobelt film
12
weight sulfur
8
β-nis nanobelts
8
concentrations glucose
8
long-term storage
8
storage test
8
nickel nanosheet
8
nanosheet film
8
ito-coated glass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!