Pushout Bond Strength in Coronal Dentin: A Standardization Approach in Comparison to Shear Bond Strength.

Materials (Basel)

Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-Universität München, Goethestr. 70, D-80336 Munich, Germany.

Published: August 2023

To find an alternative that is closer to clinical reality in terms of cavity geometry and configuration factor, this study investigated the pushout test on in vitro adhesive testing to coronal dentin when compared to the established shear test, both in a standardized approach. For a feasible comparison between both tests, the pushout specimen was adjusted in thickness (1.03 ± 0.05 mm) and cavity diameter (1.42 ± 0.03 mm) to receive a bonding area (4.63 ± 0.26 mm) that matches that of the shear test (4.57 ± 0.13 mm). Though, the configuration factor between both tests differs largely (pushout 1.5 ± 0.08; shear bond 0.20 ± 0.01). The bond strength of five different adhesives (n = 20) was investigated for both tests. The pushout test registered a high number of invalid measurements (30%) due to concomitant dentin fracture during testing. In contrast to the shear test, the pushout test failed to discriminate between different adhesives ( = 0.367). Both tests differed largely from each other when comparing adhesive groups. When solely looking at the valid specimens, Weibull modulus reached higher values in the pushout approach. Conclusively, the pushout test in this specific setup does not distinguish as precisely as the shear bond test between different adhesives and needs adaption to be routinely applied in adhesive dentistry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10456373PMC
http://dx.doi.org/10.3390/ma16165667DOI Listing

Publication Analysis

Top Keywords

pushout test
16
bond strength
12
shear bond
12
shear test
12
pushout
8
coronal dentin
8
configuration factor
8
test
8
tests pushout
8
shear
6

Similar Publications

Effect of different root canal irrigation regimes microbubble emulsion (MBE) via riboflavin photosensitizer (RFP), cerium oxide (CeO) nanoparticles (NPs), and Nd: YAP laser on antibacterial efficiency, microhardness (MH), smear layer (SL) removal efficacy, and push-out bond strength (PBS) of AH plus sealer to canal dentin. Sixty single-rooted teeth were selected, disinfected, and categorized into four groups based on the type of disinfection. Following disinfection, a pair of samples were randomly selected and visualized under scanning electron microscope (SEM) for SL evaluation.

View Article and Find Full Text PDF

Investigate the impact of antimicrobial photodynamic therapy (aPDT) using different photosensitizers (PSs) such as indocyanine green (IG), curcumin (CC), and methylene blue (MB), with or without intracanal application of calcium hydroxide (CH), on the push-out bond strength of glass-fiber posts (GFPs) to intraradicular dentin, the chemical composition of the root substrate, and the sealing of the adhesive interface across different thirds of intraradicular dentin. A total of 112 bovine teeth underwent biomechanical preparation and were divided into eight experimental groups (n = 14 each): Negative control with deionized water; positive control with deionized water + CH; IG group with indocyanine green and infrared laser; IG + CH group; CC group with curcumin and blue LED; CC + CH group; MB group with methylene blue and red laser; and MB + CH group. The push-out bond strength was measured using a universal testing machine (n = 8), and scanning electron microscopy characterized the fracture patterns.

View Article and Find Full Text PDF

Comparing Sectional and Total Dentin Bond Strengths of Three Endodontic Sealers after Using the Single-cone Obturation Technique: An Study.

J Contemp Dent Pract

October 2024

College of Dentistry, Ajman University, Ajman P.O. Box 346, United Arab Emirates; Department of Endodontic, Faculty of Dentistry, Mansoura University, Egypt, Orcid: https://orcid.org/0000-0003-3391-5306.

Aim: This study aimed to investigate and compare the total and sectional bond strengths of three endodontic sealers when used with the single-cone obturation technique.

Materials And Methods: Forty-five human maxillary central incisors were prepared and divided into three groups according to the type of endodontic sealer: Group I (Gutta-percha/AH Plus Jet), group II (Gutta-percha/GuttaFlow 2), and group III (RealSeal/RealSeal SE). All canals were filled with the single-cone technique.

View Article and Find Full Text PDF

Experimental Study on Deep-Drawing Dies Made of Pre-Stressed UHPC.

Materials (Basel)

January 2025

Chair of Metal Forming and Casting, Technical University of Munich, Walther-Meissner-Strasse 4, 85748 Garching, Germany.

Deep drawing is a cost-efficient way of producing sheet metal parts in high production volumes. Prototypes and very small series are expensive due to the cost of steel-forming tools. Ultra-high-performance concrete (UHPC) tools offer a cheap and fast alternative to conventional steel-forming tools.

View Article and Find Full Text PDF

While polyetherketoneketone is a high-performance thermoplastic polymer, its hydrophobicity and inertness limit bone adhesion. This study aimed to evaluate a novel PEKK/CaSiO/TeO nanocomposite, comparing it to PEKK/15 wt.% CaSiO and PEKK groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!