Image-to-Patient Registration in Computer-Assisted Surgery of Head and Neck: State-of-the-Art, Perspectives, and Challenges.

J Clin Med

Team IFTIM, Institute of Molecular Chemistry of University of Burgundy (ICMUB UMR CNRS 6302), Univ. Bourgogne Franche-Comté, 21000 Dijon, France.

Published: August 2023

Today, image-guided systems play a significant role in improving the outcome of diagnostic and therapeutic interventions. They provide crucial anatomical information during the procedure to decrease the size and the extent of the approach, to reduce intraoperative complications, and to increase accuracy, repeatability, and safety. Image-to-patient registration is the first step in image-guided procedures. It establishes a correspondence between the patient's preoperative imaging and the intraoperative data. When it comes to the head-and-neck region, the presence of many sensitive structures such as the central nervous system or the neurosensory organs requires a millimetric precision. This review allows evaluating the characteristics and the performances of different registration methods in the head-and-neck region used in the operation room from the perspectives of accuracy, invasiveness, and processing times. Our work led to the conclusion that invasive marker-based methods are still considered as the gold standard of image-to-patient registration. The surface-based methods are recommended for faster procedures and applied on the surface tissues especially around the eyes. In the near future, computer vision technology is expected to enhance these systems by reducing human errors and cognitive load in the operating room.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10455300PMC
http://dx.doi.org/10.3390/jcm12165398DOI Listing

Publication Analysis

Top Keywords

image-to-patient registration
12
head-and-neck region
8
registration computer-assisted
4
computer-assisted surgery
4
surgery head
4
head neck
4
neck state-of-the-art
4
state-of-the-art perspectives
4
perspectives challenges
4
challenges today
4

Similar Publications

Purpose: In mandibular reconstructive surgery with free fibula flap, 3D-printed patient-specific cutting guides are the current state of the art. Although these guides enable accurate transfer of the virtual surgical plan to the operating room, disadvantages include long waiting times until surgery and the inability to change the virtual plan intraoperatively in case of tumor growth. Alternatively, (electromagnetic) surgical navigation combined with a non-patient-specific cutting guide could be used, requiring accurate image-to-patient registration.

View Article and Find Full Text PDF

Augmented Reality in Neurosurgery.

Adv Exp Med Biol

November 2024

Department of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands.

Augmented Reality (AR) involves superimposing digital content onto the real environment. AR has evolved into a viable tool in neurosurgery, enhancing intraoperative navigation, medical education and surgical training by integrating anatomical data with the real world. Neurosurgical AR relies on several key techniques to be successful, which includes image segmentation, model rendering, AR projection, and image-to-patient registration.

View Article and Find Full Text PDF

Rigid point cloud registration based on correspondence cloud for image-to-patient registration in image-guided surgery.

Med Phys

July 2024

Digital Medical Research Center of School of Basic Medical Sciences, Fudan University, Shanghai, China.

Background: Image-to-patient registration aligns preoperative images to intra-operative anatomical structures and it is a critical step in image-guided surgery (IGS). The accuracy and speed of this step significantly influence the performance of IGS systems. Rigid registration based on paired points has been widely used in IGS, but studies have shown its limitations in terms of cost, accuracy, and registration time.

View Article and Find Full Text PDF

Achieving and maintaining proper image registration accuracy is an open challenge of image-guided surgery. This work explores and assesses the efficacy of a registration sanity check method for augmented reality-guided navigation (AR-RSC), based on the visual inspection of virtual 3D models of landmarks. We analyze the AR-RSC sensitivity and specificity by recruiting 36 subjects to assess the registration accuracy of a set of 114 AR images generated from camera images acquired during an AR-guided orthognathic intervention.

View Article and Find Full Text PDF

Today, image-guided systems play a significant role in improving the outcome of diagnostic and therapeutic interventions. They provide crucial anatomical information during the procedure to decrease the size and the extent of the approach, to reduce intraoperative complications, and to increase accuracy, repeatability, and safety. Image-to-patient registration is the first step in image-guided procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!