A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Screening for Mild Cognitive Impairment with Speech Interaction Based on Virtual Reality and Wearable Devices. | LitMetric

Significant advances in sensor technology and virtual reality (VR) offer new possibilities for early and effective detection of mild cognitive impairment (MCI), and this wealth of data can improve the early detection and monitoring of patients. In this study, we proposed a non-invasive and effective MCI detection protocol based on electroencephalogram (EEG), speech, and digitized cognitive parameters. The EEG data, speech data, and digitized cognitive parameters of 86 participants (44 MCI patients and 42 healthy individuals) were monitored using a wearable EEG device and a VR device during the resting state and task (the VR-based language task we designed). Regarding the features selected under different modality combinations for all language tasks, we performed leave-one-out cross-validation for them using four different classifiers. We then compared the classification performance under multimodal data fusion using features from a single language task, features from all tasks, and using a weighted voting strategy, respectively. The experimental results showed that the collaborative screening of multimodal data yielded the highest classification performance compared to single-modal features. Among them, the SVM classifier using the RBF kernel obtained the best classification results with an accuracy of 87%. The overall classification performance was further improved using a weighted voting strategy with an accuracy of 89.8%, indicating that our proposed method can tap into the cognitive changes of MCI patients. The MCI detection scheme based on EEG, speech, and digital cognitive parameters proposed in this study provides a new direction and support for effective MCI detection, and suggests that VR and wearable devices will be a promising direction for easy-to-perform and effective MCI detection, offering new possibilities for the exploration of VR technology in the field of language cognition.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10452416PMC
http://dx.doi.org/10.3390/brainsci13081222DOI Listing

Publication Analysis

Top Keywords

mci detection
16
effective mci
12
cognitive parameters
12
classification performance
12
mild cognitive
8
cognitive impairment
8
virtual reality
8
wearable devices
8
eeg speech
8
digitized cognitive
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!