Background: In total hip arthroplasty (THA), femoral offset restoration results in optimal biomechanics and range of motion (ROM) without bone-bone impingement. We hypothesized that differences in implant design features significantly affect bone-bone impingement risk in primary THA.

Methods: This retrospective computer simulation study included a cohort of 43 primary robotic arm-assisted THA. Considering sagittal pelvic tilt, we measured the maximum external rotation at 0° hip flexion and the maximum internal rotation at both 90° and 100° hip flexion before any bone-bone impingement occurred. To influence the offset, we included neutral or extended polyethylene liners, neutral or plus prosthetic heads, standard or high-offset stems, and stems with 132° or 127° neck angles.

Results: Extended polyethylene liner use resulted in decreased bone-bone impingement for both stems but also decreased prosthetic ROM in hip extension (mean -4.5 to 5°, range -10 to 0°) and hip flexion (mean -3 to 3.7°, range -10 to 0°) due to decreases in head diameter. Using a plus head or different stem offset/neck angle options resulted in either (1) no improvement in ROM (stem 1: 60%; stem 2: 28%) or (2) a paradoxical increase in bone-bone impingement (stem 1 with 127°: 19% and stem 2 with high offset option: 7%).

Conclusion: Counterintuitively, a subset of patients experience a paradoxical increase in bone-bone impingement when transitioning from standard to high-offset or varus necks due to the pelvic and proximal femoral bone shape. For this group of patients, preoperative personalized 3-dimensional modeling may help guide implant choice for optimizing outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10843541PMC
http://dx.doi.org/10.1016/j.arth.2023.08.057DOI Listing

Publication Analysis

Top Keywords

bone-bone impingement
24
hip flexion
12
offset restoration
8
range motion
8
total hip
8
hip arthroplasty
8
computer simulation
8
simulation study
8
0° hip
8
extended polyethylene
8

Similar Publications

Median mandibular cyst is defined as an odontogenic cyst in a rare midline location. In spite of this definition, there have been two reports of a peculiar lesion, so-called "ciliated" median mandibular cyst associated with vital teeth, the origin of which cannot be explained in terms of odontogenic epithelium multipotentiality. We describe a thorough profile of an additional example.

View Article and Find Full Text PDF

Background: Hip dislocations after total hip arthroplasty (THA) are a debilitating complication, often occurring in deep flexion. Current 3D modelling allows for simulating the flexion angle at which bone-on-bone impingement occurs, but it is resource-intensive and not widely available for routine clinical use. Therefore, we propose the ilio-femoral impingement angle (IFIa) as a novel, simple radiographic measure to help identify patients at higher risk for dislocation using standard radiographs.

View Article and Find Full Text PDF

Purpose: Studies evaluating the long-term survival rate, patient satisfaction, and conversion to total hip arthroplasty (THA) are limited. The aim of this study was to evaluate satisfaction and hip survival at a minimum 10-year follow-up in patients following hip arthroscopy for femoroacetabular impingement syndrome (FAIS).

Methods: A total of 164 patients underwent hip arthroscopy for FAIS between 2007 and 2012; of these, 76 (49 men and 27 women; mean age, 40.

View Article and Find Full Text PDF
Article Synopsis
  • Acetabular chondrolabral delamination (ACD) is a prevalent hip injury with few effective treatments; this study explored the use of PLGA conical nail fixation as a potential method.
  • The experiment involved 24 pigs with surgically induced ACD, divided into three groups: a control (no treatment), an acute fixation group using PLGA nails, and a chronic fixation group using spacers before PLGA nails.
  • Results indicated that the pigs in the acute fixation group showed significantly better cartilage regeneration and proteoglycan deposition compared to the control and chronic groups, suggesting PLGA nails are effective for treating ACD.
View Article and Find Full Text PDF

Traditionally, patients with a fracture of the distal radius are treated in a cast if they do not require surgery. If the fracture requires manipulation, the cast is moulded to hold the reduction and maintain normal anatomical alignment during healing. However, is a cast necessary for patients whose fracture does not require manipulation? Removable splints are an alternative treatment option.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!